Ground-Fault Circuit Breakers
EATON BRN115GF Type ETN01 Ground Fault Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Trip
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
EATON CH215GFT Type CH Self-Test Ground Fault Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CH240GF Type CH Ground Fault Circuit Breaker, 120/240 V AC, 40 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Quick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip-free handle design. Type CH circuit breakers trip to the off position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off the thermal magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short circuit conditions. Multi-pole breakers have internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CH250GF Type CH Ground Fault Circuit Breaker, 120/240 V AC, 50 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Quick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip-free handle design. Type CH circuit breakers trip to the off position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off the thermal magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short circuit conditions. Multi-pole breakers have internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHFGFT130 CH Series GFCI Circuit Breaker With Flag, 120 V, 30 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Trip
EATON residential CH circuit breakers provide premium overload protection. The type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CHFN120GF Type CH Self-Test Ground Fault Circuit Breaker, 120/240 V AC, 20 A, 10 kA Interrupt, 1 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON GFCB115 Type GFCB Ground Fault Circuit Breaker, 120 V AC, 15 A, 10 kA, 1 Pole
EATON GFCB115 Type GFCB Ground Fault Circuit Breaker, 120 VAC, 15 A, 10 kA, 1 Pole
EATON GFCB230 Type GFCB Ground Fault Circuit Breaker, 120/240 VAC, 30 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
EATON GFCB230 Type GFCB Ground Fault Circuit Breaker, 120/240 VAC, 30 A, 10 kA Interrupt, 2 Poles, Common Trip
EATON GFTCB220 Type GFTCB Ground Fault Circuit Breaker, 120/240 V AC, 20 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eatons BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
EATON GFTCB230 Type GFTCB Ground Fault Circuit Breaker, 120/240 VAC, 30 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
EATON GFTCB250 Type GFTCB Ground Fault Circuit Breaker, 120/240 V AC, 50 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eatons BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
GE Q-Line® THQL-2130-GFI Type THQL Model 3 Self-Test Ground Fault Circuit Breaker, 120/240 V AC, 30 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Q-Line® circuit breakers are 1 in wide per pole, compact, thermal magnetic devices designed for residential and commercial applications. the QL breakers are plug-in versions of the Q-Line® used for connection to loadcenters and lighting panels. all Q-Line® circuit breakers feature quick-make quick-break mechanisms, common trip bars and easy to spot trip indication to ensure safety and reliability. Q-Line® breakers are available in 1, 2 and 3-pole versions, can be ordered with auxiliary contact and shunt trip accessories and can be ordered for use in HID applications.
Square-D 15-AMP 1-POLE GROUND FAULT BREAKER SQU HOM-1-15-GFI
Homeline miniature circuit breakers are engineered and designed for fast installation and superior circuit protection. Homeline circuit breakers are designed to plug into Homeline load centers to provide circuit protection. This circuit breaker provides standard circuit protection and is HACR rated. This 1 pole circuit breaker with plug in mounting is rated 15A at 120 VAC. HOM breakers provide 10 kA breaking capacity. This Homeline ground fault circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. The electrical connection is a clamp terminal that will accept 2 wires. The clamp terminal will accept a wire range of 14 AWG to 8 AWG copper or aluminum wire. HOM Homeline miniature circuit breakers are UL Listed.
Square-D 15-AMP 1-POLE GROUND FAULT BREAKER SQU QO-1-15-GFI
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 1 pole QO circuit breaker is rated at 15A at 120VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
Square-D 15-AMP 1-POLE GROUND FAULT BREAKER SQU QO-2-15-GFI
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 2 pole QO circuit breaker is rated at 15A at 120/240VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
Square-D 15-AMP GROUNDFAULT CIRCUIT BREAKER SQU HOM-2-15-GFI
Homeline miniature circuit breakers are engineered and designed for fast installation and superior circuit protection. Homeline circuit breakers are designed to plug into Homeline load centers to provide circuit protection. This circuit breaker provides standard circuit protection and is HACR rated. This 2 pole circuit breaker with plug in mounting is rated 15A at 120/240 VAC. HOM breakers provide 10 kA breaking capacity. This Homeline ground fault circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. The electrical connection is a clamp terminal that will accept 2 wires. The clamp terminal will accept a wire range of 14 AWG to 8 AWG copper or aluminum wire. HOM Homeline miniature circuit breakers are UL Listed.
Square-D 20-AMP 1-POLE BOLT-ON CIRC/BREAKER SQU QO-B-1-20-GFI
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 1 pole QO circuit breaker is rated at 20A at 120VAC. This unit provides 10kA breaking capacity and bolt on mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
Square-D 20-AMP 1-POLE GROUND FAULT BREAKER SQU HOM-1-20-GFI
Homeline miniature circuit breakers are engineered and designed for fast installation and superior circuit protection. Homeline circuit breakers are designed to plug into Homeline load centers to provide circuit protection. This circuit breaker provides standard circuit protection and is HACR rated. This 1 pole circuit breaker with plug in mounting is rated 20A at 120 VAC. HOM breakers provide 10 kA breaking capacity. This Homeline ground fault circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. The electrical connection is a clamp terminal that will accept 2 wires. The clamp terminal will accept a wire range of 14 AWG to 8 AWG copper or aluminum wire. HOM Homeline miniature circuit breakers are UL Listed.
Square-D 20-AMP 2-POLE GROUND FAULT BREAKER SQU QO-220-GFI
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 2 pole QO circuit breaker is rated at 20A at 120/240VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
Square-D 20-AMP GROUND FAULT CIRC/BREAKERS SQU QO-1-20-GFI
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 1 pole QO circuit breaker is rated at 20A at 120VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
Square-D 30-AMP 1-POLE GROUND FAULT BREAKER SQU QO-1-30-GFI
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 1 pole QO circuit breaker is rated at 30A at 120VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
Square-D 30-AMP 2-POLE GROUND FAULT BREAKER SQU QO-2-30-GFI
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 2 pole QO circuit breaker is rated at 30A at 120/240VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
Square-D 30-AMP GROUNDFAULT CIRCUIT BREAKER SQU HOM-230-GFI
Homeline miniature circuit breakers are engineered and designed for fast installation and superior circuit protection. Homeline circuit breakers are designed to plug into Homeline load centers to provide circuit protection. This circuit breaker provides standard circuit protection and is HACR rated. This 2 pole circuit breaker with plug in mounting is rated 30A at 120/240 VAC. HOM breakers provide 10 kA breaking capacity. This Homeline ground fault circuit breakers provide overload and short circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 milliamperes or more. The electrical connection is a clamp terminal that will accept 2 wires. The clamp terminal will accept a wire range of 14 AWG to 8 AWG copper or aluminum wire. HOM Homeline miniature circuit breakers are UL Listed.
Square-D 40-AMP 2-POLE GROUND FAULT BREAKER SQU QO-240-GFI
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 2 pole QO circuit breaker is rated at 40A at 120/240VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a 6mA ground fault A with pigtail. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.