Plug Fuses
Bussmann BP/MB-15 Bussmann Series Mb Plug Fuse, 15 A, 125 V
Bussmann BP/TL-30 Bussmann Series Time delay Plug Fuse, 30 A, 125 V, 10 kAIC Interrupt
Bussmann BP/TL-30 Bussmann Series Time delay Plug Fuse, 30 A, 125 V, 10 kAIC Interrupt
Bussmann Fusetronâ„¢ T-15 Type T Heavy Duty Time Delay Plug Fuse, 15 A, 125 V, 10 kA Interrupt, Round Body
These fuses thread into fuse receptacles. Two types of threaded fuses are available Edison base (brass threads) and rejection base (porcelain threads). The two are not interchangeable. Two categories of plug fuses are available. The medium duty fuses (TL or SL) have a time delay feature for use on motor circuits. The heavy duty fuses (T or S) are industrial strength products featuring the exclusive Cooper Bussmann dual element construction. This spring loaded design provides superior short circuit and overload protection. The T or S fuses have more time delay than the medium duty fuses in order to better protect motors and critical residential circuits. Plug fuses are rated for a maximum of 125 VAC. TL and SL four pack (PK4) versions priced per box. Plug fuses are often used in residential and industrial branch circuit and motor protection. Fuses are used to protect furnace blower motors, pumps, power tools, garage door openers, etc. Motor protection fuses are usually used in conjunction with branch circuit protection. The fuse is often located in a box cover unit. Plug fuses provide a compact and inexpensive method to prevent damage to electrical motors. They help reduce downtime and lower maintenance costs by opening the circuit when a dangerous overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.
Bussmann SL-20PK4 Rejection Base Time Delay Plug Fuse, 20 A, 125 V AC, 10 kA Interrupt, Class: SL
Bussmann SL-20PK4 Rejection Base Time Delay Plug Fuse, 20 A, 125 VAC, 10 kA Interrupt, Class: SL
Bussmann SL-25PK4 Rejection Base Time Delay Plug Fuse, 25 A, 125 V AC, 10 kA Interrupt, Class: SL
Bussmann SL-25PK4 Rejection Base Time Delay Plug Fuse, 25 A, 125 VAC, 10 kA Interrupt, Class: SL
Bussmann SL-30PK4 Rejection Base Time Delay Plug Fuse, 30 A, 125 V AC, 10 kA Interrupt, Class: SL
These fuses thread into fuse receptacles. Two types of threaded fuses are available Edison base (brass threads) and rejection base (porcelain threads). The two are not interchangeable. Two categories of plug fuses are available. The medium duty fuses (TL or SL) have a time delay feature for use on motor circuits. The heavy duty fuses (T or S) are industrial strength products featuring the exclusive Cooper Bussmann dual element construction. This spring loaded design provides superior short circuit and overload protection. The T or S fuses have more time delay than the medium duty fuses in order to better protect motors and critical residential circuits. Plug fuses are rated for a maximum of 125 VAC. TL and SL four pack (PK4) versions priced per box. Plug fuses are often used in residential and industrial branch circuit and motor protection. Fuses are used to protect furnace blower motors, pumps, power tools, garage door openers, etc. Motor protection fuses are usually used in conjunction with branch circuit protection. The fuse is often located in a box cover unit. Plug fuses provide a compact and inexpensive method to prevent damage to electrical motors. They help reduce downtime and lower maintenance costs by opening the circuit when a dangerous overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.
Bussmann TL-20PK4 Type TL Time Delay Plug Fuse, 20 A, 125 VAC, 10 kA Interrupt
EATON BP/MB-20 Bussmann Series Mb Plug Fuse, 20 A, 125 V
EATON Bussmann TL-30PK4 Type TL Time Delay Plug Fuse, 30 A, 125 V AC, 10 kA Interrupt
EATON Bussmann TL-30PK4 Type TL Time Delay Plug Fuse, 30 A, 125 VAC, 10 kA Interrupt
Littelfuse® POWR-GARD® SOO025 Plug Fuse, 25 A, 125 VAC, 10 kA
Littelfuse® SOO015 Time Delay Plug Fuse, 15 A, 125 VAC, 10 kA, Round Body
Littelfuse® SOO020 Time Delay Plug Fuse, 20 A, 125 VAC, 10 kA, Round Body
Littelfuse® TLO020 Time Delay Plug Fuse, 20 A, 125 VAC, 10 kA, Round Body
Littelfuse® TLO025 Time Delay Plug Fuse, 25 A, 125 VAC, 10 kA, Round Body
Littelfuse® TOO015 TOO Medium Time Delay Plug Fuse, 15 A, 125 VAC, 10 kA Interrupt, Round Body
TOO Fuses are dual-element time delay Edison-base fuses designed for motor and motor branch-circuit protection; also suitable for all general purpose circuits. Use for replacement purposes only.
Littelfuse® TOO020 Medium Time Delay Plug Fuse, 20 A, 125 VAC, 10 kA, Round Body
Littelfuse® TOO025 Medium Time Delay Plug Fuse, 25 A, 125 VAC, 10 kA, Round Body
Littelfuse® TOO030 Medium Time Delay Plug Fuse, 30 A, 125 VAC, 10 kA, Round Body
Recently Viewed
15" BLACK ADJUSTABLE WRENCH - ALL26115 >
TELESCOPING ALG/CLIP MATCH HOLDERS-GNL400>
CHAINSAW FILE ORANGE HANDLES-WIN6604 >
12" BLACK ADJUSTABLE WRENCH - ALL26112 >
6' X 6' 14-MIL GREEN VINYL WELDING SCREEN AND FRAME - RII645166>
10" ADJUSTABLE WRENCH - ALL26110 >