Littelfuse® POWR-GARD® NLN600 Fast Blow One Time Fuse, 600 A, 250 V AC/DC, 50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
-
BrandLittelfuse®
-
UPC079458360981
-
Manufacturer Part NumberNLN600
-
CountryUSA|Canada
-
Terminal TypeKnife Blade
-
ClassK5
-
Frequency Rating50/60 Hz
-
TypeFast Blow
-
Mounting TypeHolder
-
Voltage Rating250 V AC/DC
-
Amperage Rating600 A
-
SeriesNLN
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating50 kA
-
Body Size2-19/32 in Dia x 10-3/8 in L
-
Body TypeCartridge
-
ElementSingle
- For use in applications where lowest initial cost is the major consideration
- Economical
- 50 kA at 250 VAC (rms symmetrical) and 50 kA at 250 VDC interrupt rating
- Safety - 50000 A.I.R., Class K5 adequate interrupting capacity for residences and many smaller facilities
-
Alternative Part Number0NLN600.X|8586913
-
UNSPSC39121627
-
IDEA Index ID8586913
-
Package DescriptionEACH
-
Standards/ApprovalsUL E81895|CSA LR29862, Standard 248-9
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® NLN600 Fast Blow One Time Fuse, 600 A, 250 V AC/DC, 50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
MORSE® 45010 1895 6-Piece Double End Non-Center Cutting Regular Length End Mill Set, 4 Flutes, Bright
SM SBN02.0 Nipple
THE ARC ABRASIVES NARROW BELT IS SPECIFICALLY ENGINEERED FOR APPLICATIONS SUCH AS: STOCK REMOVAL, DEBURRING, FLASH REMOVAL, SURFACE PREPARATION, AND FINISHING. PERFECT FOR USE ON ALUMINUM AND VARIOUS METALS.
ARC70254PM >
Proto® J49532S2 1-Piece Roll Pin Punch, 5/32 in Parabolic Punch, 5-1/4 in OAL, Steel
4-BIT TECHNICIAN SCREWDRIVER-GNL608 >