Littelfuse® POWR-GARD® NLS070 Fast Blow One Time Fuse, 70 A, 600 V AC/DC, 50 kA Interrupt, Class: K5, Cartridge Body
NLS series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
-
BrandLittelfuse®
-
UPC079458370799
-
Manufacturer Part NumberNLS070
-
CountryUSA|Canada
-
Terminal TypeKnife Blade
-
ClassK5
-
TypeFast Blow
-
Mounting TypeHolder
-
Voltage Rating600 V AC/DC
-
Amperage Rating70 A
-
SeriesNLS
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating50 kA
-
Body Size1-5/16 in Dia x 7-7/8 in L
-
Body TypeCartridge
- For use in applications where lowest initial cost is the major consideration
- Economical
- 50 kA at 600 VAC (rms symmetrical) and 50 kA at 600 VDC interrupt rating
- Safety - 50000 A.I.R., Class K5 adequate interrupting capacity for residences and many smaller facilities
-
Alternative Part Number0NLS070.V|8587070
-
UNSPSC39121627
-
IDEA Index ID8587070
-
Package DescriptionEACH
-
Standards/ApprovalsUL E81895|CSA LR29862, Standard 248-9|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® NLS070 Fast Blow One Time Fuse, 70 A, 600 V AC/DC, 50 kA Interrupt, Class: K5, Cartridge Body
NLS series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
1/2" HAMMERDRILL KIT-BSH1194VSRK>
GP® 1016R Standard Length Socket, 3/8 in Drive, 1/2 in Socket, 6 Points
MORSE® 33722 2068 General Purpose Straight Flute Hand Tap, Right Hand Cutting, #5-40 Thread, H2 Thread Limit, Plug Chamfer, 3 Flutes, Bright, HSS
4" MECHANICS ROUND SCREWDRIVER-CRE21434V >
MORSE® 38106 7500 General Purpose Straight Flute Hand Tap, Right Hand Cutting, M5x0.8 Thread, D4 Thread Limit, Bottoming Chamfer, 4 Flutes, Bright, HSS

