Littelfuse® POWR-GARD® NLN006 Fast Blow One Time Fuse, 6 A, 250 V AC/DC, 20/50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
-
BrandLittelfuse®
-
UPC079458360585
-
Manufacturer Part NumberNLN006
-
CountryUSA
-
Terminal TypeFerrule
-
ClassK5
-
Frequency Rating50/60 Hz
-
TypeFast Blow
-
Mounting TypeHolder
-
Voltage Rating250 V AC/DC
-
Amperage Rating6 A
-
SeriesNLN
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating20/50 kA
-
Body Size9/16 in Dia x 2 in L
-
Body TypeCartridge
-
ElementSingle
- For use in applications where lowest initial cost is the major consideration
- Economical
- 50 kA at 250 VAC (rms symmetrical) and 20 kA at 250 VDC interrupt rating
- Safety - 50000 A.I.R., Class K5 adequate interrupting capacity for residences and many smaller facilities
-
Alternative Part Number0NLN006.T|8586673
-
UNSPSC39121627
-
IDEA Index ID8586673
-
Package DescriptionEACH
-
Standards/ApprovalsUL E81895|CSA LR29862, Standard 248-9|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® NLN006 Fast Blow One Time Fuse, 6 A, 250 V AC/DC, 20/50 kA Interrupt, Class: K5, Cartridge Body
NLN series fuses provide low cost protection for general purpose feeder and branch circuits when available short circuit currents are less than 50000 A. They replace all Class H fuses which have only a 10000 A interrupting rating. They are suitable for use in many residential and smaller commercial and industrial applications. NLKP series fuses are Canadian "Code" fuses specifically designed to meet Canadian electrical code type P fuse requirements for residential use. They have a 10000 A interrupting rating. However, to obtain the added benefits of time delay, current limitation and higher interrupting rating, consider the use of POWR-PRO® IDSR Indicator fuses for circuits between 250 and 600 V. The user gets all the benefits of time delay RK5 fuses plus the added benefits of a n indicating fuse that tells when it has opened. complete information on these fuses may be found in the POWR-PRO® section of this catalog. for circuits upto 250 V, see FLNR fuses in this section of the catalog.
MORSE® 38523 7501 General Purpose Spiral Point Tap, M14x1.5 Thread, D6 Thread Limit, Plug Chamfer, 3 Flutes, Bright, HSS
MORSE® 38523 7501 General Purpose Spiral Point Tap, M14x1.5 Thread, D6 Thread Limit, Plug Chamfer, 3 Flutes, Bright, HSS
Gardner Bender PS-175 UV-Resistant Electrical Staple, 12 AWG, 14 AWG Cable, Plastic
These polyethylene staples with zinc plated nails are designed to offer fast and easy installation when securing most types of non-metallic cables. The zinc plated nails not only resist rust and corrosion but drive together for fast installation with a hammer while the recessed heads ensure minimum exposure and avoid snags. The smooth polyethylene saddle protects wire and will not rust, rot or deteriorate. Use to attach all NM cable to joists, framing and other wood installations.
Charlotte PVC 02309 2000, 4 in nominal, Socket end style, SCH 40/STD, PVC, Domestic
PVC Schedule 40 fitting that is for pressure systems where temperatures will not exceed 140° F. They are highly resilient, with high-tensile and high-impact strength. PVC Schedule 40 has better sound deadening qualities than
10-24" X 5/16" Round Head Slot Machine Screws
MORSE® 14624 1396 1-Stage Type A Heavy Duty Jobber Length Aircraft Drill, #21 Drill - Wire, 0.159 in Drill - Decimal Inch, 118 deg Point, HSS
MORSE® 14624 1396 1-Stage Type A Heavy Duty Jobber Length Aircraft Drill, #21 Drill - Wire, 0.159 in Drill - Decimal Inch, 118 deg Point, HSS