Littelfuse® POWR-GARD® JLLS250 Current Limiting Fast Acting Fuse, 250 A, 600 V AC/300 V DC, 20/200 kA Interrupt, T Class, Cartridge Body
Space saving Class T fuses are the most compact fuses available in ratings above 30 A - less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide Fast Acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection.
-
BrandLittelfuse®
-
UPC079458190908
-
Manufacturer Part NumberJLLS250
-
CountryUSA
-
Terminal TypeKnife Blade
-
MaterialMelamine
-
ClassT
-
TypeCurrent Limiting
-
Mounting TypeHolder
-
Voltage Rating600 V AC/300 V DC
-
Amperage Rating250 A
-
SeriesJLLS
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating20/200 kA
-
Body Size1.593 in Dia x 3.625 in L
-
Body TypeCartridge
- Extremely current- limiting compact design
- Protection of individual electric services and meters
- Used to provide compact protection for meter stacks
- Current limiting design greatly reduces damage to equipment caused by heating and magnetic effects of short circuit currents
- 200 kA AC rms symmetrical and 20 kA DC interrupt rating
- Copper caps
| Competitor Name | Competitor Part Number |
|---|---|
| Grainger | 486M13 |
-
Alternative Part NumberJLLS250.X|8580340
-
UNSPSC39121627
-
IDEA Index ID8580340
-
Package DescriptionEACH
-
Standards/ApprovalsUL 248-15|UL E81895|CSA Certified|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® JLLS250 Current Limiting Fast Acting Fuse, 250 A, 600 V AC/300 V DC, 20/200 kA Interrupt, T Class, Cartridge Body
Space saving Class T fuses are the most compact fuses available in ratings above 30 A - less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide Fast Acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection.
50 LB OF#20 POLE BARN NAILS-JWH729643 >
1-QT LIQUID TRIOXVEGETATION KILLER-JWH713062 >
R12+ Dropheads ship completely assembled and ready to use with HSS segmental dies already in place. R12+ Dropheads can be used manually with the ratchet ring and handle or with REED's 700PD, 700APD and 701PD Power Drives. R12+ dropheads are interchangeable with RIDGID® 12-R dropheads and can also be utilized in the RIDGID® 700 power drive.
ShearTap™ 34484 2091 Oversized Spiral Flute Tap, Right Hand Cutting, 1/2-20 Thread, H3 Thread Limit, Semi-Bottoming Chamfer, Right Hand Flute Direction, 3 Flutes, Black Steam Oxide, HSS
ShearTap™ offers exceptional value for high volume tapping. The geometry is optimized for long-chipping steels and stainless steels up to a hardness of 35Rc. Made with premium high speed steel with an enhanced flute design, the ShearTap™ offer great chip management, cutting edge strength and wear resistance, resulting in a high quality threads.
BBI 042138 Fully Threaded Cap Screw, 3/8-16, 1 in L Under Head, 8 Grade, Alloy Steel, Zinc Yellow Bake CR+6