Littelfuse® POWR-GARD® JLLN110 Current Limiting Fast Acting Fuse, 110 A, 300 V AC, 20/200 kA Interrupt, T Class, Cartridge Body
Space saving Class T fuses are the most compact fuses available in ratings above 30 A - less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide Fast Acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection.
-
BrandLittelfuse®
-
UPC079458180831
-
Manufacturer Part NumberJLLN110
-
CountryUSA
-
Terminal TypeKnife Blade
-
MaterialMelamine
-
ClassT
-
TypeCurrent Limiting
-
Mounting TypeHolder
-
Voltage Rating300 V AC
-
Amperage Rating110 A
-
SeriesJLLN
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating20/200 kA
-
Body Size1.062 in Dia x 2.437 in L
-
Body TypeCartridge
- Extremely current- limiting compact design
- Protection of individual electric services and meters
- Used to provide compact protection for meter stacks
- Current limiting design greatly reduces damage to equipment caused by heating and magnetic effects of short circuit currents
- 200 kA AC rms symmetrical and 20 kA DC interrupt rating
- Copper caps
- North American style
| Competitor Name | Competitor Part Number |
|---|---|
| Grainger | 486L80 |
-
Alternative Part NumberJLLN110.X|8580027
-
UNSPSC39121627
-
IDEA Index ID8580027
-
Package DescriptionEACH
-
Standards/ApprovalsUL 248-15|UL E81895|CSA Certified|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® JLLN110 Current Limiting Fast Acting Fuse, 110 A, 300 V AC, 20/200 kA Interrupt, T Class, Cartridge Body
Space saving Class T fuses are the most compact fuses available in ratings above 30 A - less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide Fast Acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection.
Diversitech 145-175220 Variable Motor Start Capacitor, 145 to 175 uF, 220/250 V AC, Round
This DiversiTech® 145-175220 Motor Start Capacitor, 145-175µF, 220/250 volts motor start, electrolytic, non-polarized capacitor is designed for normal intermittent service on single-phase A/C motor starting circuits.
Cutler-Hammer 10250T102 10250T Heavy Duty Oil/Watertight Pushbutton, 30.5 mm, Red
Cutler-Hammer 10250T102 10250T Heavy Duty Oil/Watertight Pushbutton, 30.5 mm, Red
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.
EATON C25DND330A Definite Purpose Contactor, 110 to 120 V AC V Coil, 30 A Inductive/40 A Resistive, 3 Poles
EATON offers the most complete line of definite purpose (DP) contactors in the industry. Designed for heating, ventilation, air conditioning and refrigeration (HVACR) applications, EATON DP contactors are designed to handle the most challenging installations.
Square D™ QO™ QO120DF Dual Function Combination Miniature Circuit Breaker, 120 V AC, 20 A, 10 kA Interrupt, 1 Pole, Thermal Magnetic Trip
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 1 pole QO circuit breaker is rated at 20A at 120VAC. This unit provides 10kA breaking capacity and plug in mounting. This product includes a dual function feature with pigtail. This provides combination arc fault and ground fault protection. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.