Edison TJS20 Very Fast Acting Fuse, 20 A, 600 V AC, 200 kA Interrupt, T Class
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.
-
BrandEdison
-
UPC782634807155
-
Manufacturer Part NumberTJS20
-
CountryUSA
-
ClassT
-
Voltage Rating600 V AC
-
Amperage Rating20 A
-
SeriesTJS
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating200 kA
-
Body Size0.56 in Dia x 1.5 in L
- No intentional time delay, opens quickly on overload
- Extremely current-limiting silver link construction; provides superior short-circuit component protection
- Use to protect lower interrupting rating circuit breakers when series rated with Class T fuses
- For motor protection, size at 300% FLA which provides short circuit protection only
-
Alternative Part Number8431416
-
UNSPSC39121626
-
IDEA Index ID8431416
-
Package DescriptionEACH
-
Standards/ApprovalsBAA Compliant|CE Certified|C22.2 No 248.15|Class 1422-02|CSA Certified|Guide JDDZ|Std. 248-15|UL Listed
-
Catalog
-
Specification Sheet
Recently Viewed
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.
Littelfuse® TOO030 Medium Time Delay Plug Fuse, 30 A, 125 VAC, 10 kA, Round Body
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.
Bussmann NON-40 Non-Current Limiting One Time Fuse, 40 A, 250 VAC, 125 VDC, 50 kA Interrupt, Class: H/K5, Cylindrical Body
Bussmann NON-40 Non-Current Limiting One Time Fuse, 40 A, 250 VAC, 125 VDC, 50 kA Interrupt, Class: H/K5, Cylindrical Body
Cutler-Hammer H1057 H Series Overload Relay Heater
Industrial grade locking devices are designed for quick and easy installation and provide reliable performance in tough industrial environments.