Edison TJS125 Very Fast Acting Fuse, 125 A, 600 V AC, 200 kA Interrupt, T Class
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.
-
BrandEdison
-
UPC782634807278
-
Manufacturer Part NumberTJS125
-
CountryUSA
-
ClassT
-
Voltage Rating600 V AC
-
Amperage Rating125 A
-
SeriesTJS
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating200 kA
-
Body Size3-1/4 in L
- No intentional time delay, opens quickly on overload
- Extremely current-limiting silver link construction; provides superior short-circuit component protection
- Use to protect lower interrupting rating circuit breakers when series rated with Class T fuses
- For motor protection, size at 300% FLA which provides short circuit protection only
-
Alternative Part Number8431512
-
UNSPSC39121626
-
IDEA Index ID8431512
-
Package DescriptionEACH
-
Standards/ApprovalsCE Certified|C22.2 No 248.15|Class 1422-02|CSA Certified|Guide JDDZ|Std. 248-15|UL Listed
-
Catalog
-
Specification Sheet
Recently Viewed
Edison TJS125 Very Fast Acting Fuse, 125 A, 600 V AC, 200 kA Interrupt, T Class
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.
Bussmann SL-20PK4 Rejection Base Time Delay Plug Fuse, 20 A, 125 V AC, 10 kA Interrupt, Class: SL
Bussmann SL-20PK4 Rejection Base Time Delay Plug Fuse, 20 A, 125 VAC, 10 kA Interrupt, Class: SL
Bussmann SL-30PK4 Rejection Base Time Delay Plug Fuse, 30 A, 125 V AC, 10 kA Interrupt, Class: SL
These fuses thread into fuse receptacles. Two types of threaded fuses are available Edison base (brass threads) and rejection base (porcelain threads). The two are not interchangeable. Two categories of plug fuses are available. The medium duty fuses (TL or SL) have a time delay feature for use on motor circuits. The heavy duty fuses (T or S) are industrial strength products featuring the exclusive Cooper Bussmann dual element construction. This spring loaded design provides superior short circuit and overload protection. The T or S fuses have more time delay than the medium duty fuses in order to better protect motors and critical residential circuits. Plug fuses are rated for a maximum of 125 VAC. TL and SL four pack (PK4) versions priced per box. Plug fuses are often used in residential and industrial branch circuit and motor protection. Fuses are used to protect furnace blower motors, pumps, power tools, garage door openers, etc. Motor protection fuses are usually used in conjunction with branch circuit protection. The fuse is often located in a box cover unit. Plug fuses provide a compact and inexpensive method to prevent damage to electrical motors. They help reduce downtime and lower maintenance costs by opening the circuit when a dangerous overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.
Edison TJN110 Very Fast Acting Fuse, 110 A, 300 V AC, 200 kA Interrupt, T Class
Edison's Class T current-limiting, fast-acting fuses. Provides 10X better current limitation to help prevent equipment damage caused by short-circuit events. 200 kA Interrupting rating complies with NEC Section 110.9 for today’s large capacity systems. Small, space-saving fuses provide a high degree of current limitation on short-circuits for excellent component protection.