Littelfuse® POWR-GARD® SLC008 Current Limiting Medium Acting Time Delay Fuse, 8 A, 600 V AC, 100 kA Interrupt, G Class, Cartridge Body
The unique design of Littelfuse® compact SLC series Class G fuses provide additional time delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuse's varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fuses' superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. Littelfuse® introduction of POWR-PRO® CCMR series fuses, with ratings upto 60 A for providing branch circuit protection are accelerating this trend.
-
BrandLittelfuse®
-
UPC079458420630
-
Manufacturer Part NumberSLC008
-
CountryUSA|Canada
-
Terminal TypeFerrule
-
ClassG
-
TypeCurrent Limiting Medium Acting
-
Mounting TypeHolder
-
Voltage Rating600 V AC
-
Amperage Rating8 A
-
SeriesSLC
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating100 kA
-
Body Size13/32 in Dia x 1-5/16 in L
-
Body TypeCartridge
- Current limiting design reduces damage to equipment caused by heating and magnetic effects of short circuit currents
- Medium time-delay allows fuses to be sized closer to actual equipment requirements no need to greatly oversize to withstand harmless equipment or system surges
- Medium time-delay may reduce downtime caused by power surges or equipment demands
- 100 kA at 600 VAC interrupting rating
| Competitor Name | Cross-Reference Number |
|---|---|
| Grainger | 486K28 |
-
Alternative Part Number0SLC008.T|8588165
-
UNSPSC39121627
-
IDEA Index ID8588165
-
Package Description10/BX
-
Standards/ApprovalsUL 248-5|E81895|CSA Certified|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® SLC008 Current Limiting Medium Acting Time Delay Fuse, 8 A, 600 V AC, 100 kA Interrupt, G Class, Cartridge Body
The unique design of Littelfuse® compact SLC series Class G fuses provide additional time delay over competitive products which increases system reliability. Compact Class G fuses were the first fuse series to approach midget fuse dimensions and meet NEC requirements for branch-circuit protection. The unique dimensions of SLC series Class G fuses prevents insertion of lower voltage fuses in Class G fuse holders. The fuse's varying length prevents insertion of higher ampere rated fuses in fuse holders designed for lower ampere ratings. Class CC fuses are replacing Class G fuses in many new designs. Class CC fuses' superior time delay plus higher voltage and interrupting ratings meet the needs of modern circuits. Littelfuse® introduction of POWR-PRO® CCMR series fuses, with ratings upto 60 A for providing branch circuit protection are accelerating this trend.
Littelfuse® POWR-GARD® JLLS150 Current Limiting Fast Acting Fuse, 150 A, 600 V AC/300 V DC, 20/200 kA Interrupt, T Class, Cartridge Body
Space saving Class T fuses are the most compact fuses available in ratings above 30 A - less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide Fast Acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection.
Littelfuse® POWR-GARD® JLLN110 Current Limiting Fast Acting Fuse, 110 A, 300 V AC, 20/200 kA Interrupt, T Class, Cartridge Body
Space saving Class T fuses are the most compact fuses available in ratings above 30 A - less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide Fast Acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection.
LEVITON LEV 2631 30-AMP 277-VOLT BLACK/WHITE 2-POLE 3-WIRE LOCKING ELECTRICAL MALE PLUG
Leviton® industry leading locking devices, such as our Black & White® line of industrial grade plugs and connectors and receptacles, offer superior performance, long lasting reliability and other features that are backed by a lifetime warranty.
Littelfuse® POWR-GARD® JLLS125 Current Limiting Fast Acting Fuse, 125 A, 600 V AC/300 V DC, 20/200 kA Interrupt, T Class, Cartridge Body
Space saving Class T fuses are the most compact fuses available in ratings above 30 A - less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide Fast Acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection.
Littelfuse® POWR-GARD® JLLN250 Current Limiting Fast Acting Fuse, 250 A, 300 V AC/125 V DC, 20/200 kA Interrupt, T Class, Cartridge Body
Space saving Class T fuses are the most compact fuses available in ratings above 30 A - less than one-third the size of comparable Class R fuses. When rated in accordance with the NEC, Class T fuses provide Fast Acting overload and short circuit protection for non-inductive circuits and equipment. Used in inductive circuits, the ampere rating of Class T fuses must be increased to prevent opening on inrush currents. In such instances, Class T fuses may provide only short circuit protection.