Littelfuse® POWR-GARD® LFR254001C Fuse Block, 250 V AC, 400 A, Class: R, 1/0 AWG to 350 kcmil Wire, 1 Poles
The new Littelfuse® class H and R blocks offer many advantages over previous generations that are noted in the features and benefits section. Class H and class R fuse blocks are dimensionally the same, but class R blocks incorporate A rejection feature, which only allows class R fuses to be inserted.
-
BrandLittelfuse®
-
UPC079458181623
-
Manufacturer Part NumberLFR254001C
-
CountryUSA|Canada
-
Temperature Rating130 deg C
-
MaterialThermoplastic
-
ClassR
-
Fuse Diameter2.406 in
-
Fuse Length8.626 in
-
Connection TypeBox Lug
-
Mounting TypeDIN Rail
-
Voltage Rating250 V AC
-
Amperage Rating400 A
-
SeriesLFR
-
Wire Size1/0 AWG to 350 kcmil
-
Number of Poles1
-
Dimensions11.5 in L x 3.5 in W x 3.32 in H
-
Suitable For Use WithFLNR/FLNR_ID, KLNR and LLNRK Series Fuse
- Universal mounting holes for easy replacement
- Only 1-hand is required to release from DIN rail (lock open lock closed)
- Reinforced fuse clips are standard on all class H and class R fuse blocks
- <0.6 mA at 600 VAC leakage current
- 200 kA rms symmetrical withstand rating
- Clip designs maximize electrical contact and minimize heat rise
- DIN rail releasable for all non-knife blade style fuses
- Lead (Pb) free
- Indication offered on most 250 and 600 VAC versions
-
Alternative Part Number11126706
-
UNSPSC39121629
-
IDEA Index ID11126706
-
Package DescriptionEACH
-
Standards/ApprovalsRoHS Compliant|UL Listed|CSA Certified|94 V-0 Flammability Rating|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer.
-
Specification Sheet
-
Owners/User Manual
Recently Viewed
Littelfuse® POWR-GARD® LFR254001C Fuse Block, 250 V AC, 400 A, Class: R, 1/0 AWG to 350 kcmil Wire, 1 Poles
The new Littelfuse® class H and R blocks offer many advantages over previous generations that are noted in the features and benefits section. Class H and class R fuse blocks are dimensionally the same, but class R blocks incorporate A rejection feature, which only allows class R fuses to be inserted.
Littelfuse® POWR-GARD® JTD350 Current Limiting Time Delay Fuse, 350 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
Littelfuse® POWR-GARD® JTD225 Current Limiting Time Delay Fuse, 225 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
Littelfuse® POWR-GARD® JTD300 Current Limiting Time Delay Fuse, 300 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
Edison ECNR75 ECNR Current Limiting Time Delay Fuse, 75 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
Littelfuse® POWR-GARD® JTD600 Current Limiting Time Delay Fuse, 600 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.