EATON FIRE-GUARD® BRCAF115 Type BRC Combination Arc-Fault Circuit Breaker, 120 VAC, 15 A, 10 kA Interrupt, 1 Pole, Thermal Magnetic Trip
EATON's type BR (1 in) combination AFCI is available in 15 and 20 A configurations and includes options for 22 kAIC interrupting rating. Eaton has also made a diagnostic version of the BR arc fault which includes an led, indicating the most recent trip code to assist in troubleshooting.
-
BrandEATON
-
UPC786685514321
-
Manufacturer Part NumberBRCAF115
-
CountryUSA
-
Temperature Rating60 to 75 deg C
-
Trip TypeThermal Magnetic
-
TypeType BRC Combination
-
Connection TypeStandard Pigtail
-
Mounting TypePlug-On
-
Voltage Rating120 V AC
-
Amperage Rating15 A
-
Wire Size14 to 4 AWG
-
Number of Poles1
-
Dimensions6 in L x 3-1/2 in W x 1-1/4 in H
-
Interrupt Rating10 kA
- 1 in combination
- Compact footprint as standard
- Arc fault detection methodology tolerant of non-compliant devices
- Lifetime trip code retention
- Overvoltage protection
- Continuous self-test of electronic components
| Competitor Name | Cross-Reference Number |
|---|---|
| Ferguson | CBRCAF115 |
-
UNSPSC39121603
-
Package DescriptionEACH
-
Standards/ApprovalsARRA Compliant|Buy American Act Compliant|RoHS Compliant|UL 1699|Federal Specification W-C-375|PROP65: This product can expose you to chemicals including: Nickel compounds, which is known to the State of California to cause cancer and Bisphenol A (BPA), which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
-
Specification Sheet
-
Catalog
Recently Viewed
EATON FIRE-GUARD® BRCAF115 Type BRC Combination Arc-Fault Circuit Breaker, 120 VAC, 15 A, 10 kA Interrupt, 1 Pole, Thermal Magnetic Trip
EATON's type BR (1 in) combination AFCI is available in 15 and 20 A configurations and includes options for 22 kAIC interrupting rating. Eaton has also made a diagnostic version of the BR arc fault which includes an led, indicating the most recent trip code to assist in troubleshooting.
EATON FIRE-GUARD® BRL220AF Type BR AFCI Circuit Breaker, 120/240 VAC, 20 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
EATON FIRE-GUARD® BRL220AF Type BR AFCI Circuit Breaker, 120/240 VAC, 20 A, 10 kA Interrupt, 2 Poles, Common Trip
EATON FIRE-GUARD® BRL215CAF Type BR Combination Arc-Fault Circuit Breaker, 120/240 V AC, 15 A, 10 kAIC Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
HCI Preferred Supplier 17042420 Hydraulic Elbow Adapter, 1-7/8-12 x 1-1/4 in Nominal, 37 deg JIC x Code 61 Flange End Style, Steel
HCI Preferred Supplier 17042420 Hydraulic Elbow Adapter, 1-7/8-12 x 1-1/4 in Nominal, 37 deg JIC x Code 61 Flange End Style, Steel
HCI Preferred Supplier FSO240446 Hydraulic Adapter, 9/16-18 x 3/8-18 Nominal, Male O-Ring Face Seal x MNPT, Steel
HCI Preferred Supplier FSO240446 Hydraulic Adapter, 9/16-18 x 3/8-18 Nominal, Male O-Ring Face Seal x MNPT, Steel