Drillco 350E002 3500E Imperial Plain Combined Drill and Countersink, 5/64 in Drill - Fraction, 0.0781 in Drill - Decimal Inch, 60 deg Included Angle, 60 deg Point Angle, HSS, Uncoated
When metal parts are machined on centers, as in turning or cylindrical grinding, it is always necessary to drill and countersink the center holes to serve as seats or bearings in the machine centers.
-
BrandDrillco
-
UPC045996999198
-
Manufacturer Part Number350E002
-
CountryUSA|Canada
-
FinishUncoated
-
Point Angle60 deg
-
Point Diameter5/64 in
-
MaterialHSS
-
TypeImperial Plain
-
Series3500E
-
Shank Size3/16 in
-
Cutting DirectionRight Hand
-
Cutting Edge MaterialHSS
-
Included Angle60 deg
-
Drill Size - Decimal Inch0.0781 in
-
Drill Size - Fraction5/64 in
-
Body Diameter3/16 in
-
Overall Length1-7/8 in
- Plain type with single 60 chamfer
- Bright finish for added lubricity
- Double ended for twice the life
- Double ended for twice the life
-
UNSPSC20121600
-
Package Description1/PK
-
SDS
-
Catalog
Recently Viewed
Drillco 350E002 3500E Imperial Plain Combined Drill and Countersink, 5/64 in Drill - Fraction, 0.0781 in Drill - Decimal Inch, 60 deg Included Angle, 60 deg Point Angle, HSS, Uncoated
When metal parts are machined on centers, as in turning or cylindrical grinding, it is always necessary to drill and countersink the center holes to serve as seats or bearings in the machine centers.
Carbon Steel Taps are used to rethread damaged or jammed threads, or to thread mild steels. They can be used for either through or blind holes. Taper Pipe Tap (NPT).
EATON CH330 Type CH Standard Circuit Breaker, 240 V AC, 30 A, 10 kA Interrupt, 3 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CH315 Type CH Standard Circuit Breaker, 240 V AC, 15 A, 10 kA Interrupt, 3 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CH350 Type CH Standard Circuit Breaker, 240 V AC, 50 A, 10 kA Interrupt, 3 Poles
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
Drillco 350E006 3500E Imperial Plain Combined Drill and Countersink, 7/32 in Drill - Fraction, 0.2188 in Drill - Decimal Inch, 60 deg Included Angle, 60 deg Point Angle, HSS, Uncoated
When metal parts are machined on centers, as in turning or cylindrical grinding, it is always necessary to drill and countersink the center holes to serve as seats or bearings in the machine centers.


