Leviton® GFWT2-I Duplex Feed Through Self-Test Slim Tamper/Weather Resistant GFCI Receptacle With Ivory Test, Reset Button, 125 V AC, 20 A, 2 Poles, 3 Wires, Ivory
Peace of mind, all the time. The SmartlockPro® self test GFCI tests itself even if you forget. Designed to meet the latest UL standard for auto-monitoring (self test) our complete line of self test GFCIs periodically conduct an automatic internal test to confirm that it can respond to a ground fault. With the slimmest profile ON the market, the device allows for fast and easy installation, while Leviton® patented reset lockout mechanism prevents reset of the GFCI if it is not wired or operating correctly. The SmartlockPro® self test GFCI is the smart choice in ground fault circuit interrupter protection.
-
BrandLeviton®
-
UPC078477709160
-
Manufacturer Part NumberGFWT2-I
-
CountryUSA
-
Temperature Rating-35 to 66 deg C
-
Terminal TypeBack/Side Wire
-
MaterialPolycarbonate
-
ColorIvory
-
TypeDuplex Feed Through Self-Test Slim Tamper/Weather Resistant
-
GradeCommercial/Residential/Specification
-
NEMA RatingNEMA 5-20R
-
Voltage Rating125 V AC
-
Amperage Rating20 A
-
Horsepower1 hp
-
Number of Poles2
-
Dimensions4.21 in H x 1.69 in W x 1.4 in D
-
Number of Wires3
- Provides continuous ground fault protection detects and trips on actual ground fault even when self-test is being conducted
- On initial power up, tests the GFCI circuit within 3 sec
- Auto monitoring exceeds the UL requirement
- Auto adapts and shifts to more frequent testing if potential problem is detected
- Status indicator light provides simple, intuitive feedback on power and protection status as well as indication of line load reversal
- Patented lockout action prevents reset if GFCI is damaged and cannot respond to a ground fault
- Electronics are designed to minimize any false triggers
- Reduced depth makes it easier to install in any electrical box, even shallow ones
- External back wire clamps provide visual indication of proper wire seating
- Withstands high torque and resists wire pullout
- Stainless steel strap and screws, cold impact resistant face and buttons
- Trip threshold meets or exceeds UL requirements for tripping time
- Improved immunity to high frequency noise reduces nuisance tripping
- Advanced electronics design provides superior resistance to electrical surges and over voltages
- Compatible with all Decora® devices and wallplates
-
Alternative Part Number13219383
-
UNSPSC39121406
-
IDEA Index ID13219383
-
Package DescriptionEACH
-
Standards/ApprovalsANSI C73|CSA C22.2 No. 144.1-06/42 File No. LR57811|Federal Specification WC596|MIL-SPEC A-A-55459-SB|NOM Certified|UL 498/943 File No. E48380
-
Specification Sheet
-
Owners/User Manual
Recently Viewed
Leviton® GFWT2-I Duplex Feed Through Self-Test Slim Tamper/Weather Resistant GFCI Receptacle With Ivory Test, Reset Button, 125 V AC, 20 A, 2 Poles, 3 Wires, Ivory
Peace of mind, all the time. The SmartlockPro® self test GFCI tests itself even if you forget. Designed to meet the latest UL standard for auto-monitoring (self test) our complete line of self test GFCIs periodically conduct an automatic internal test to confirm that it can respond to a ground fault. With the slimmest profile ON the market, the device allows for fast and easy installation, while Leviton® patented reset lockout mechanism prevents reset of the GFCI if it is not wired or operating correctly. The SmartlockPro® self test GFCI is the smart choice in ground fault circuit interrupter protection.
PAIR PRECISION THRUST BALL BEARING-FAF3MM205WIDUL>
Browning 16-TOOTH Q-BUS #100 CHAIN SPROCKET BRW H-100-Q-16
Browning® offers a variety of bushing type sprockets available in single and double strands. Offerings include 35 to 160 pitch range. Bushed type bore ranges are available from 1/2 to 5 in. Hardened teeth are available up to 30 teeth.
SWANSON TL043M Torpedo Level Digital Torpedo Magnetic Levels, 9 in L, 4 Vials, Aluminum, 0.0005 in Accuracy
Square-D 30-AMP 2-POLE 120-VOLT CONTACTORS SQU 8910-DPA-32-V-02
8910DP definite purpose magnetic contactors are designed for heating, air conditioning and refrigeration applications. This line of definite purpose contactors has current ratings up to 120 amperes resistive and 50 HP at 600 VAC. This two pole definite purpose contactor has a full load rating of 30 ampere and a resistive rating of 40 amperes. It also has a 2 HP at 115 VAC single phase, 5 HP at 230 VAC single phase and 10 HP at 230 VAC three phase, 15 HP at 460 VAC three phase and 20 HP at 575 VAC three phase. The nonreplaceable coil is available with a variety of coil voltages. This device has a 110/120 VAC 50/60 Hz coil. The contactor has straight through wiring. Contactor is 3.75 inches by 2.37 inches and 3.00 tall. These contactors are UL component recognized and CSA certified.
HCI Preferred Supplier HSS-12 Band Clamp, 11/16 to 1-1/2 in Nominal, 60 mm THK, 301 Stainless Steel
HCI Preferred Supplier 620016 Band Clamp, 11/16 to 1-1/2 in Nominal, 60 mm THK, 301 Stainless Steel