Eaton
Edison KON35 One-Time Fuse, 35 A, 250 VAC, 10 kA Interrupt, Class: Class K5
Edison KON40 One-Time Fuse, 40 A, 250 VAC, 10 kA Interrupt, Class: Class K5
Edison KOS10 One-Time Fast-Acting Fuse, 10 A, 600 V, 10 kAIC Interrupt, Class: H
Edison KOS10 One-Time Fast-Acting Fuse, 10 A, 600 V, 10 kAIC Interrupt, Class: H
Edison KOS20 One-Time Fast-Acting Fuse, 20 A, 600 V, 10 kAIC Interrupt, Class: K5
Edison KOS20 One-Time Fast-Acting Fuse, 20 A, 600 V, 10 kAIC Interrupt, Class: K5
Edison KOS50 One-Time Fast-Acting Fuse, 50 A, 600 V, 10 kAIC Interrupt, Class: K5
Edison KOS50 One-Time Fast-Acting Fuse, 50 A, 600 V, 10 kAIC Interrupt, Class: K5
Edison LKN-30 Non-Current Limiting Renewable Fuse Link, 250 V AC, 30 A, For Use With REN-30 Class H 0.81 in Dia x 3 in L Fuse
Edison LKN-30 Non-Current Limiting Renewable Fuse Link, 250 VAC, 30 A, For Use With REN-30 Class H 0.81 in Dia x 3 in L Fuse
Edison LKS-150 Non-Current Limiting Renewable Fuse Link, 600 VAC, 150 A, For Use With RES-150 Class H 9.63 in L Fuse
Edison LKS-150 Non-Current Limiting Renewable Fuse Link, 600 VAC, 150 A, For Use With RES-150 Class H 9.63 in L Fuse
Edison LKS-250 Replacement Fuse Link, 600 V AC, 250 A, For Use With RES-250 Class H/K5 Super Lag Renewable Non Current-Limiting Fuses
Edison LKS-250 Replacement Fuse Link, 600 VAC, 250 A, For Use With RES-250 Class H/K5 Super Lag Renewable Non Current-Limiting Fuses
Edison MaxiĀ® MAX-80 Fast Acting Automotive Fuse, 80 A, 32 V DC, 1 kA Interrupt
MaxiĀ® fuses protect circuits in the wiring harness usually found under the hood, in a fuse panel or supplementary panel near the battery. Ideal for aftermarket accessories (such as high end stereos) that require protection up to 80 A.
Edison MCL1 Fast Acting Midget Fuse, 1 A, 600 VAC, 100 kA Interrupt
Edison MCL5 Fast Acting Midget Fuse, 5 A, 600 VAC, 100 kA Interrupt
Edison MCL6 Fast Acting Midget Fuse, 6 A, 600 VAC, 100 kA Interrupt
Edison MDA-7 Small Dimension Time Delay Fuse With Nickel Plated Brass End Caps, 7 A, 250 VAC, 200 A/10 kA Interrupt, Cylindrical Body
Edison MDA-7 Small Dimension Time Delay Fuse With Nickel Plated Brass End Caps, 7 A, 250 VAC, 200 A/10 kA Interrupt, Cylindrical Body
Edison MEN1.4 Time Delay Midget Fuse, 1.4 A, 250 VAC, 10 kA Interrupt
Edison MEN1.5 Time Delay Midget Fuse, 1.5 A, 250 VAC, 10 kA Interrupt
Edison MEN1.8 Time Delay Midget Fuse, 1.8 A, 250 VAC, 10 kA Interrupt
Edison MEN10 Midget Fuse, 10 A, 250 V, 10 kA, Time Delay
Edison MEN15 Midget Fuse, 15 A, 250 V, 10 kA, Time Delay
Edison MEN20 Midget Fuse, 20 A, 250 V, 10 kA, Time Delay
Edison MEN3 Midget Fuse, 3 A, 250 V, 10 kA, Time Delay
Edison MEN5 Midget Fuse, 5 A, 250 V, 10 kA, Time Delay
Edison MEN7 Time Delay Midget Fuse, 7 A, 250 VAC, 10 kA Interrupt
Edison MEQ1.25 Time Delay Midget Fuse, 1.25 A, 500 VAC, 10 kA Interrupt
Edison MEQ1.5 Time Delay Midget Fuse, 1.5 A, 500 VAC, 10 kA Interrupt
Recently Viewed
Used as in-line protection for fluorescent fixtures, the LittelfuseĀ® LGR and LMF series fuses and LHR holder offer increased safety and reliability to lighting systems. On a 277 VAC system, a fault occurring in an un-fused fixture could take out the entire branch circuit affecting upto 100 fixtures. This could cause safety problems as well as shut down operations. By individually fusing fixtures, these problems will be avoided. The added benefits of this is the ability to quickly identify the problem fixture and reduce the repair time. Fuse holders are rated upto 10 A at 300 VAC and are equipped with 7 in 18 AWG leads. Order part number LHR 000 for two leads and part number LHR 001 for one lead and one terminal for insertion of 18 AWG ballast lead.
GENERALĀ® TL100 Standard Test Lead With Boots, 300 VAC, 10 A, 3 ft OAL
3/4" NM PUSH-IN CONNECTOR
EATON E50KL201 Adjustable Roller Heavy Duty Plug-In Limit Switch Operator, Nylatron Roller
Eaton's E50 modular plug-in limit switches are the industry standard with versatility of design and high reliability for low maintenance, installation and inventory costs. Standard Viton gaskets, seals and boots and a zinc die -cast enclosure provide exceptional chemical resistance to the common coolants, cleansing agents and hydraulic fluids found in machine tool, automotive, wastewater treatment and other heavy-duty industrial applications. Mounting dimensions accommodate both U.S. and DIN standards for easy retrofit installations. Super bright 24 ā 120 Vac/Vdc LED indicating light versions simplify setup and troubleshooting operations.
EATON Power Defense⢠PDG63P2000E4ZN Globally Rated Molded Case Circuit Breaker, 600 V AC, 2000 A, 100 kA at 480 V/65 kA at 600 V Interrupt, 3 Poles, Electronic Trip
The Power Defense⢠molded case circuit breaker portfolio is globally rated in a small footprint for easy adaptability no matter the application or project requirement. A circuit breaker with communicating electronic trip units and the ability to generate the data to help you optimize your facilities performance and to help keep your employees, customers and end-users safe by reducing the risk of arcflash events.
EATON 10250T4 Heavy Duty Oiltight/Watertight Non-Illuminated Push-Pull Operator, 30.5 mm, 2NC Contact, 3 Positions
Eaton's 10250T line of 30.5 mm pushbuttons features a heavy-duty zinc die cast construction. Reliability nibs improve contact reliability even under dry circuit and fine dust conditions. In addition, drainage holes prevent the buildup of liquid inside the operator, which can prevent operation in freezing environments.