Littelfuse® POWR-GARD® JTD110 Current Limiting Time Delay Fuse, 110 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
-
BrandLittelfuse®
-
UPC079458202250
-
Manufacturer Part NumberJTD110
-
CountryUSA|Canada
-
Terminal TypeKnife Blade
-
MaterialMelamine
-
ClassJ
-
TypeCurrent Limiting
-
Mounting TypeHolder
-
Voltage Rating600 V AC/500 V DC
-
Amperage Rating110 A
-
SeriesJTD
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating200/20 kA
-
Body Size1-1/2 in Dia x 5-3/4 in L
-
Body TypeCartridge
-
ElementDual
- Reduced down time - A glance at the indicating window of a JTD_ID indicator fuse pinpoints open fuses immediately
- Machine operators can immediately determine that there is an open fuse and request maintenance personnel to bring the proper replacement
- Reduce nuisance opening - indicator fuses have superior time-delay and cycling characteristics they can be used on a variety of applications, thus decreasing fuse inventory
- Reduce fuse inventory - Because JTD_ID indicator fuses have superior performance characteristics they can be used on a variety of applications, thus decreasing fuse inventory
- Reduce equipment damage - indicator fuses provide superior overload and short circuit protection that can reduce equipment damage
- Indicator fuses also provide IEC type II "No Damage" protection to IEC and NEMA type motor starters
- Reduce accidents the JTD_ID indicator fuse improves safety by minimizing exposure to live circuits
- IEC type 2 protection
- 200 kA rms symmetrical at 600 VAC/20 kA at 500 VDC
| Competitor Name | Cross-Reference Number |
|---|---|
| Grainger | 486J88 |
-
Alternative Part Number0JTD110.X|8580835
-
UNSPSC39121609
-
IDEA Index ID8580835
-
Package DescriptionEACH
-
Standards/ApprovalsUL 248-8 File No.E81895|CSA File No.LR29862|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® JTD110 Current Limiting Time Delay Fuse, 110 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
1-1/4"-ID SPH/OD INSERT BEARINGS-FAF1104KRRB>
1" -8" USS NC HAND PLUG TAP-PDTEK5016084P >
24 STANDARD DBL RIVET ANGLE BEAMS-PNC46SB24C >
5/16" GLASS & TILE DRILLBIT-JWH328146 >
Edison JDL3 Current Limiting Time Delay Fuse, 3 A, 600 V AC, 200/300 kA, Class J
Edison's UL Class J fuse products are offered in both Dual-Element Time-Delay (JDL) and Fast-Acting (JFL) types. Both types have 200,000 amp interrupting rating at 600Vac RMS Sym amps. Their small physical size and high performance characteristics makes Class J fuses ideal for any space-limited applications. Edison's JFL fuses are best suited for the protection of non-inductive loads such as resistive heating and lighting circuits.