Edison JDL3 Current Limiting Time Delay Fuse, 3 A, 600 V AC, 200/300 kA, Class J
Edison's UL Class J fuse products are offered in both Dual-Element Time-Delay (JDL) and Fast-Acting (JFL) types. Both types have 200,000 amp interrupting rating at 600Vac RMS Sym amps. Their small physical size and high performance characteristics makes Class J fuses ideal for any space-limited applications. Edison's JFL fuses are best suited for the protection of non-inductive loads such as resistive heating and lighting circuits.
-
BrandEdison
-
UPC782634803348
-
Manufacturer Part NumberJDL3
-
CountryUSA
-
Terminal TypeFerrule
-
ClassJ
-
Response Time10 s
-
TypeCurrent Limiting
-
Voltage Rating600 V AC
-
Amperage Rating3 A
-
SeriesJDL
-
Interrupt Rating200/300 kA
-
Body Size0.81 in Dia x 2.25 in L
-
ElementDual
- True dual element fuses with a minimum 10 sec time delay at 500% overload
- Long time delay minimizes needless fuse openings due to temporary overloads and transient surges
- Can often be sized for back up protection against motor burnout from overload or single phasing if other overload protective devices fail
- High interrupt rating to safely interrupt over currents up to 300 kA
- High deg of current limitation due to the fast speed of response to short circuits
- Faster response to damaging short circuit currents than mechanical over current protective devices
- Reduces let through thermal and magnetic forces in order to protect low withstand rated components
- Dual element fuses have lower resistance than ordinary fuses, hence they run cooler
- Lower watts loss reduces power consumption
- Unique dimensions assure that another class of fuse with a lesser voltage rating, interrupt rating or current limiting ability cannot be substituted
- Space saving package for equipment down sizing
- Proper sizing provides "No Damage" type 2 coordinated protection for NEMA and IEC motor control in accordance with IEC standard 947-4-1
-
Alternative Part Number8430293
-
UNSPSC39121626
-
IDEA Index ID8430293
-
Package DescriptionEACH
-
Standards/ApprovalsUL Listed|Guide JDDZ, UL File No. E162363|CSA C22.2, No. 248.8
-
Specification Sheet
Recently Viewed
Edison JDL3 Current Limiting Time Delay Fuse, 3 A, 600 V AC, 200/300 kA, Class J
Edison's UL Class J fuse products are offered in both Dual-Element Time-Delay (JDL) and Fast-Acting (JFL) types. Both types have 200,000 amp interrupting rating at 600Vac RMS Sym amps. Their small physical size and high performance characteristics makes Class J fuses ideal for any space-limited applications. Edison's JFL fuses are best suited for the protection of non-inductive loads such as resistive heating and lighting circuits.
3/4" ROUND SPRING SNAPS-NTL222745 >
ITM 201SD9664 Bit Shank Drill, 1-1/2 in Drill - Fraction, 1.5 Drill - Decimal Inch, 1/2 in Shank, M2 HSS
ITM 201SD9664 Bit Shank Drill, 1-1/2 in Drill - Fraction, 1.5 Drill - Decimal Inch, 1/2 in Shank, M2 HSS
Carhartt® CHB620DT Safety Glasses, Anti-Fog/Anti-Scratch, Gray Lens, Black/Tan, Polycarbonate Frame, ANSI Z87.1+
Klein® 44100 Utility Knife With Retractable Blade, Retractable Blade, Steel Blade, 4 Blades Included, 6 in OAL
The Klein Tools Retractable Blade Utility Knife features a 1-Inch double-ended and reversible blade for efficient cutting. The handle is made from aluminum for a lightweight feel, and can be used with most standard blades. The top button can be moved to put the blade in 3 different cutting positions or can be retracted for safety.
Browning®Type B minimum bore sprockets are offered in single, double and triple strands. Offerings include 25 to 200 pitch range. Minimum bore sprockets are available in bore ranges from 1/4 to 8-3/8 in.