Connecticut Electric View-Pak™ VPKUBIF030N UBIF Type NC Thin Replacement Circuit Breaker, 120 V AC, 30 A, 10 kA Interrupt, 1 Poles
Connecticut Electric View-Pak™ VPKUBIF030N UBIF Type NC Thin Replacement Circuit Breaker, 120 VAC, 30 A, 10 kA Interrupt, 1 Poles, Thermal/Magnetic Trip
-
BrandConnecticut Electric
-
UPC094925006025
-
Manufacturer Part NumberVPKUBIF030N
-
CountryUSA
-
Temperature Rating40 deg C
-
MaterialDMC
-
Frequency Rating50/60 Hz
-
Trip TypeThermal/Magnetic
-
TypeType NC Thin
-
Connection TypePush-On
-
Actuator TypeHandle
-
Voltage Rating120 V AC
-
Amperage Rating30 A
-
SeriesUBIF
-
Number of Poles1
-
Dimensions1 in L x 4 in W x 6 in H
-
Interrupt Rating10 kA
-
Phase1
| Cross-Reference Number |
|---|
| 516347 |
-
Alternative Part Number11929790
-
UNSPSC39121601
-
IDEA Index ID11929790
-
Package DescriptionEACH
-
Standards/ApprovalsETL Listed|CE Certified|UL 489
-
Warranty5 years
-
Catalog
-
Specification Sheet
Recently Viewed
Connecticut Electric View-Pak™ VPKUBIF030N UBIF Type NC Thin Replacement Circuit Breaker, 120 V AC, 30 A, 10 kA Interrupt, 1 Poles
Connecticut Electric View-Pak™ VPKUBIF030N UBIF Type NC Thin Replacement Circuit Breaker, 120 VAC, 30 A, 10 kA Interrupt, 1 Poles, Thermal/Magnetic Trip
Irwin® Hanson® 1218 General Purpose Straight Flute Tap, Right Hand Cutting, #6-32 Thread, Bottoming Chamfer, 3 Flutes, High Carbon Steel
Littelfuse® POWR-GARD® JTD200 Current Limiting Time Delay Fuse, 200 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
Wilton® 38114 Heavy Duty Straight Pipe Wrench, 2 in Pipe, 14 in OAL, Floating Hook Jaw, Ductile Cast Iron Handle
Wilton® 38114 Heavy Duty Straight Pipe Wrench, 2 in Pipe, 14 in OAL, Floating Hook Jaw, Ductile Cast Iron Handle
EATON FIRE-GUARD™ CH215CAF Type CH Combination Arc Fault Circuit Breaker, 120/240 VAC, 15 A, 10 kA Interrupt, 2 Poles
EATON's CH ground fault current interrupters (GFCIs) are 3/4 in W and provide superior safety over a standard electrical outlet in areas where electricity may come into contact with water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs and outdoor receptacles. They immediately break the circuit when electrical current leakage is detected, reducing the risk of shock and electrocution.
Littelfuse® POWR-GARD® JTD100 Current Limiting Time Delay Fuse, 100 A, 600 V AC/300 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.