Drillco 77A116C 7700 Center Cutting Imperial Regular Length Single End Ball Nose End Mill, 1/4 in Dia Cutter, 3/4 in Length of Cut, 4 Flutes, 1/4 in Dia Shank, 2-1/2 in OAL, Uncoated
Solid carbide end mills run at extremely impressive feed and speed rates. In some cases, they can be run at 3x the rates of HSS end mills. Using solid carbide end mills results in better surface finish on the workpiece and extended tool life. Ball nose.
-
BrandDrillco
-
UPC045997392110
-
Manufacturer Part Number77A116C
-
CountryUSA|Canada
-
FinishUncoated
-
MaterialSolid Carbide
-
TypeCenter Cutting Imperial Regular Length Single End
-
Series7700
-
Cutter Diameter1/4 in
-
Shank Diameter1/4 in
-
Number of Flutes4
-
Shank TypeRound
-
Length of Cut3/4 in
-
Overall Length2-1/2 in
- Solid carbide construction for extreme rigidity and strength
- Ball nose for profiling and grooving with radii, and contouring
- 4 flutes produce a better surface finish and less chatter
- Bright finish for added lubricity
-
UNSPSC27112803
-
Package Description1/PK
-
Standards/ApprovalsPROP65: This product can expose you to chemicals including Cobalt, which is [are] known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.
-
SDS
-
Catalog
Recently Viewed
Drillco 77A116C 7700 Center Cutting Imperial Regular Length Single End Ball Nose End Mill, 1/4 in Dia Cutter, 3/4 in Length of Cut, 4 Flutes, 1/4 in Dia Shank, 2-1/2 in OAL, Uncoated
Solid carbide end mills run at extremely impressive feed and speed rates. In some cases, they can be run at 3x the rates of HSS end mills. Using solid carbide end mills results in better surface finish on the workpiece and extended tool life. Ball nose.
Brady® PBL2 Emergency Stop Safety Cover, For Use With Lockout Device, Steel, Silver, ANSI Z244, NFPA-704, NPCA-HMIS, OSHA 29 CFR 1910.147(C) (4)(ii)( A)(1)/(c) (5)(ii)(C)(1)
Guard against unauthorized operation or accidental activation of push, pull or twist-release emergency stops with Emergency Stop Safety Covers from Brady®.
Square Dâ„¢ QO270 Standard Miniature Circuit Breaker, 120/240 V AC, 70 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 2 pole QO circuit breaker is rated at 70A at 120/240VAC. This unit provides 10kA breaking capacity and plug in mounting. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
Sealmaster 1-3/4"-ID 4-BOLT SPH FLANGE UNITS BRW SFC-1000-NE X 1-3/4
Sealmaster® USRB performance mounted spherical roller bearings feature black oxide treated bearing steel races with optimized bearing geometry for load capacity, misalignment and speed capabilities. The USRB is available in both setscrew locking and adapter mounting system. The felt seal with flinger provides a good balance between contaminant entry, grease retention and friction. Depending on application requirements, these bearings are available in a wide variety of bore sizes, housing styles and sealing options.
EATON CH215GFT Type CH Self-Test Ground Fault Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
PILLOBALL self-aligning Rod Ends can be used as link mechanisms in a variety of machines and are designed for easy installation.

