Browning® 3749736 Taper Lock Bushing, 2-3/16 in Dia Bore, 3-3/8 in Dia Barrel, 1-3/4 in OAL, Steel
Browning® 3749736 Taper Lock Bushing, 2-3/16 in Dia Bore, 3-3/8 in Dia Barrel, 1-3/4 in OAL, Steel
-
BrandBrowning®
-
UPC662289616435
-
Manufacturer Part Number3749736
-
CountryUSA
-
Taper1-1/2 in/ft
-
MaterialSteel
-
Torque Rating11600 in-lb
-
Screw Size1/2 x 1 in
-
Number of Bolt Holes2
-
Barrel Diameter3-3/8 in
-
Keyway Size1/2 x 1/4 in
-
Bolt Circle Diameter3-1/4 in
-
Bore Diameter2-3/16 in
-
Overall Length1-3/4 in
-
Suitable For Use WithBrowning® Sprockets and HPT Chain Synchronous Belt Drives
- Size 2517 bushing
- Mounts flush in products no protruding flanges to interfere with the drive
- Key to key drive cap screws act as an external key
- 1-1/2 in/ft taper on barrel since this is a non-self locking taper it provides ease of installation and removal of products from the shaft
-
Alternative Part Number2517X 2 3/16
-
UNSPSC31163205
-
Package DescriptionEACH
-
Warranty1 Year
-
Catalog
-
Instruction/Installation Manual
Recently Viewed
Browning® 3749736 Taper Lock Bushing, 2-3/16 in Dia Bore, 3-3/8 in Dia Barrel, 1-3/4 in OAL, Steel
Browning® 3749736 Taper Lock Bushing, 2-3/16 in Dia Bore, 3-3/8 in Dia Barrel, 1-3/4 in OAL, Steel
Square D™ QO235 Standard Miniature Circuit Breaker, 120/240 V AC, 35 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
QO and QOB one, two and three pole thermal magnetic circuit breakers provide overcurrent protection and switching on ac and dc systems. These circuit breakers have an over center, trip free toggle mechanism with quick make, quick break action and positive handle indication. They also have VisiTrip trip indication, which provides a visual indication that the circuit breaker has tripped and interrupted the circuit. A full line of features and factory installed accessories are also available such as shunt trips, auxiliary switches and alarm switches. This 2 pole QO circuit breaker is rated at 35A at 120/240VAC. This unit provides 10kA breaking capacity and plug in mounting. QO circuit breakers are UL Listed under UL File E84967 and are CSA Certified under CSA Master Contract 153555.
3/4" X 144" EYE/EYE WIREROPE SLING-SWC8FAB876 >
MORSE® 56765 5972G Center Cutting Regular Length Roughing End Mill, 5/8 in Dia Cutter, 1-1/4 in Length of Cut, 4 Flutes, 5/8 in Dia Shank, 3-1/2 in OAL, TiN Coated
32 TOOTH SPROCKETS FOR #35 CHAIN-IDC35B32F1 >
Dichtomatik N70347 O-Ring, 347 Dash Number, 4.225 in ID x 4.645 in OD, Nitrile Rubber, 70 Shore A Durometer, Import
O-rings are closed circular rings of circular cross-section. They are made through vulcanization from form tools as a complete ring. The sealing function of the O-ring is achieved by the deformation of the cross-section when installed and compressed in its housing. The O-ring can be compressed either radially or axially in its installation housing. In operating conditions the pressure exerted by the media reinforces the sealing function, as under pressure the elastomer material functions as a non-compressible fluid.

