Southwire® 13054255 Type UF-B Underground Feeder Cable With Grounding Wire, 600 V AC, (2) 14 AWG Copper Conductor, 250 ft L
Southwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90C (with ampacity limited to that for 60C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.
-
BrandSouthwire®
-
UPC032886166006
-
Manufacturer Part Number13054255
-
CountryUSA
-
Temperature Rating90 deg C
-
TypeType UF-B
-
Conductor Size14 AWG
-
Conductor TypeCopper
-
Voltage Rating600 V AC
-
Amperage Rating15 A
-
Number of Conductors2
-
Insulation MaterialPVC
-
Jacket ColorGray
-
Jacket MaterialNylon
-
Strands1
-
Outside Diameter423 x 168 mil
-
Length250 ft
- Brand received (Cerrowire or Southwire) varies by zip code
- Available with 2 or 3 conductors with or without a ground wire
- Conductors are made of annealed (soft) copper
- UF-B cable may be used underground, including direct burial
- Moisture, fungus, sunlight-resistant
-
Alternative Part Number14/2|8876249
-
UNSPSC26121517
-
IDEA Index ID8876249
-
Package DescriptionEACH
-
Standards/ApprovalsARRA Compliant|Buy American Act Compliant|RoHS Compliant|UL 83|UL 493|Federal Specification A-A-59544|NEC Certified|NFPA 70-2011 Edition
-
Warranty1 Year
-
Specification Sheet
Recently Viewed
Southwire® 13054255 Type UF-B Underground Feeder Cable With Grounding Wire, 600 V AC, (2) 14 AWG Copper Conductor, 250 ft L
Southwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90C (with ampacity limited to that for 60C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.
BBI 390300 Flat Washer, 1 in ID x 2 in OD, 0.105 in THK, 304 Stainless Steel
Southwire® 13059155 Type UF-B Underground Feeder Cable With Grounding Wire, 600 V AC, (3) 10 AWG Copper Conductor, 250 ft L
Southwire® copper UF-B cable is generally used as feeder to outside post lamps, pumps, and other loads or apparatus fed from a distribution point in an existing building as specified in the 2011 National Electrical Code. UF-B cable may be used underground, including direct burial. Multiple conductor UF-B cable may be used for interior branch circuit wiring in residential or agricultural buildings at conductor temperatures not to exceed 90C (with ampacity limited to that for 60C conductors) as specified by the National Electrical Code. UF-B can be used in applications permitted for NMC in Section 334.10(B) of the National Electrical Code. Voltage rating for UF-B cable is 600 volts.
7/8" -9 USS NC PLUG HAND TAP-PDTEK5014094P >
15" RECORD STORAGE BOX SUPPORTS-PNC46BS15 >
3/4" -10 USS PLUG HAND TAP-PDTEK5012103P >