NIBCO 1-1/4" S-80 PVC 90-DEG SXFPT ELBOW NIB 807-012
Lasco® 807-012, 1-1/4 in nominal, Socket x FNPT end style, SCH 80/XH, PVC, Domestic
-
BrandLasco®
-
UPC025528719975
-
Manufacturer Part Number807-012
-
CountryUSA
-
MaterialPVC
-
Fitting/Connector Type90 deg Elbow
-
Method of ManufactureInjection-Molded
-
ColorGray
-
Schedule RatingSCH 80/XH
-
Nominal Size1-1/4 in
-
Domestic/ImportDomestic
-
End StyleSocket x FNPT
- ASTM D-1784: Rigid poly vinyl chloride (PVC) compounds and chlorinated poly vinyl chloride (CPVC) compounds
- ASTM D-2464: Threaded poly vinyl chloride (PVC) plastic pipe fittings SCH 80/XH
- ASTM D-2467: Socket type poly vinyl chloride (PVC) plastic pipe fittings
- NSF/ANSI standard 61, Annex G: Drinking water system components weighted average lead content of less than or equal to 0.25% and is in compliance with California's health and safety code section 116875 (commonly known as AB1953) NSF/ANSI Standard 14: Plastics piping system components and related materials, includes ANSI standard 61, Annex G
- Do not use Lasco® fittings for compressed air or gases
- Do not test PVC piping systems with compressed air or gases
- Do not use fittings with liquids not recommended by Lasco®
- Fitting modification voids the warranty
-
UNSPSC40172808
-
Package Description10/CTN
-
Standards/ApprovalsASTM D1784|ASTM D2464|ASTM D2467|NSF/ANSI 14|NSF/ANSI 61|Annex-G
-
WarrantyLimited
-
Catalog
-
Specification Sheet
Recently Viewed
Lasco® 807-012, 1-1/4 in nominal, Socket x FNPT end style, SCH 80/XH, PVC, Domestic
Charlotte PVC 02401 0600, Tee, 1/2 in nominal, Socket x Socket x FNPT end style, SCH 40/STD, PVC, Domestic
PVC Schedule 40 fitting that is for pressure systems where temperatures will not exceed 140° F. They are highly resilient, with high-tensile and high-impact strength. PVC Schedule 40 has better sound deadening qualities than
PVC Male Adapter, Socket x MPT, 1-1/4" Pipe Size
Charlotte PVC 02112 2000, 1 x 3/4 in nominal, MNPT x FNPT end style, SCH 40/STD, PVC, Domestic
PVC Schedule 40 fitting that is for pressure systems where temperatures will not exceed 140° F. They are highly resilient, with high-tensile and high-impact strength. PVC Schedule 40 has better sound deadening qualities than
Creates a long 90 degree bend in your PVC sewer piping system and changes the piping system to a spigot or hub termination.
Charlotte PVC 02109 1200, 1-1/4 in nominal, Socket x MNPT end style, SCH 40/STD, PVC, Domestic
PVC Schedule 40 fitting that is for pressure systems where temperatures will not exceed 140° F. They are highly resilient, with high-tensile and high-impact strength. PVC Schedule 40 has better sound deadening qualities than