Edison ECNR80 ECNR Current Limiting Time Delay Fuse, 80 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5, Cylindrical Body
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
-
BrandEdison
-
UPC782634507413
-
Manufacturer Part NumberECNR80
-
CountryUSA
-
Terminal TypeBlade End
-
MaterialFiberglass
-
ClassRK5
-
Rejection/Non-RejectionRejection
-
Response Time10 s at 500%
-
TypeCurrent Limiting Time Delay
-
Voltage Rating250 V AC/125 V DC
-
Amperage Rating80 A
-
SeriesECNR
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating200 kAIC
-
Body Size1.06 in Dia x 5.88 in L
-
Body TypeCylindrical
-
ElementDual
- Provides motor overload, ground fault and short circuit protection
- Helps protect motors against burnout from 1 ph on 3 ph systems
- Simplifies and improves blackout prevention (selective co-ordination ratios)
- Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is 5X greater than the amperage rating of the fuse for a minimum of 10 s
- Superior overload and cycling capabilities
- True dual element construction allows sizing of 125% FLA for motor backup protection
- Current limiting provides component short circuit protection
- For all general purpose applications including lighting, heating and other non-inductive loads
- Tin plated copper brass terminal and zinc plated steel screws
-
Alternative Part Number11197141
-
UNSPSC39121606
-
IDEA Index ID11197141
-
Package DescriptionEACH
-
Standards/ApprovalsCE Marked
-
Specification Sheet
Recently Viewed
Edison ECNR80 ECNR Current Limiting Time Delay Fuse, 80 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5, Cylindrical Body
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
GALVANIZED CLAMPS 2-1/2" X 5/8"-BNDJ-309 >
2-GRV FINISHED BORE SHEAVE 1-1/8" BORE-BRW2BK40X11/8 >
1/2" FEMALE HYDRAULIC FEMALE JIC CAPS-DAY304C8 >
Krylon® A00342007 Industrial Spray Paint, 16 oz Container, Red Oxide, 20 to 25 sq-ft Coverage, 15 min Curing
United Abrasives-SAIT 71057 2A Premium Coated Flap Wheel, 2-1/2 in Dia, 1 in W Face, 120 Grit, Fine Grade, Aluminum Oxide Abrasive