Edison ECNR75 ECNR Current Limiting Time Delay Fuse, 75 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
-
BrandEdison
-
UPC782634507574
-
Manufacturer Part NumberECNR75
-
CountryUSA
-
MaterialFiberglass
-
ClassRK5
-
Response Time10 s at 500%
-
TypeCurrent Limiting Time Delay
-
Voltage Rating250 V AC/125 V DC
-
Amperage Rating75 A
-
SeriesECNR
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating200 kAIC
-
Body Size1.06 in Dia x 5.88 in L
-
ElementDual
- Superior overload and cycling capabilities
- True dual-element construction allows sizing of 125% FLA for motor backup protection
- Current-limiting provides component short-circuit protection
- Recommended for AC power distribution system mains, feeders and branch circuits
- Protection of motors and motor branch circuits
- Protection of transformers and other inductive loads
-
Alternative Part Number11197152|16876334
-
UNSPSC39121606
-
IDEA Index ID11197152
-
Package DescriptionEACH
-
Standards/ApprovalsCE Certified
-
Catalog
-
Specification Sheet
Recently Viewed
Edison ECNR75 ECNR Current Limiting Time Delay Fuse, 75 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
LittelfuseĀ® POWR-GARDĀ® JTD600 Current Limiting Time Delay Fuse, 600 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The LittelfuseĀ® POWR-PROĀ® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
Edison ECNR3.2 ECNR Current Limiting Time Delay Fuse, 3.2 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
EATON BR115 Type BR Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Trip
Eatonās BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
Connecticut Electric View-Pak⢠VPKUBIF030N UBIF Type NC Thin Replacement Circuit Breaker, 120 V AC, 30 A, 10 kA Interrupt, 1 Poles
Connecticut Electric View-Pak⢠VPKUBIF030N UBIF Type NC Thin Replacement Circuit Breaker, 120 VAC, 30 A, 10 kA Interrupt, 1 Poles, Thermal/Magnetic Trip
IrwinĀ® HansonĀ® 1218 General Purpose Straight Flute Tap, Right Hand Cutting, #6-32 Thread, Bottoming Chamfer, 3 Flutes, High Carbon Steel