Edison ECNR60 ECNR Current Limiting Time Delay Fuse, 60 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5, Cylindrical Body
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
-
BrandEdison
-
UPC782634507390
-
Manufacturer Part NumberECNR60
-
CountryUSA
-
Terminal TypeFerrule End
-
MaterialFiberglass
-
ClassRK5
-
Rejection/Non-RejectionRejection
-
Response Time10 s at 500%
-
TypeCurrent Limiting Time Delay
-
Voltage Rating250 V AC/125 V DC
-
Amperage Rating60 A
-
SeriesECNR
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating200 kAIC
-
Body Size0.81 in Dia x 3 in L
-
Body TypeCylindrical
-
ElementDual
- Provides motor overload, ground fault and short circuit protection
- Helps protect motors against burnout from 1 ph on 3 ph systems
- Simplifies and improves blackout prevention (selective co-ordination ratios)
- Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is 5X greater than the amperage rating of the fuse for a minimum of 10 s
- Superior overload and cycling capabilities
- True dual element construction allows sizing of 125% FLA for motor backup protection
- Current limiting provides component short circuit protection
- For all general purpose applications including lighting, heating and other non-inductive loads
- Tin plated copper brass terminal and zinc plated steel screws
| Competitor Name | Competitor Part Number |
|---|---|
| Grainger | 12W260 |
-
Alternative Part Number11197139|13663990
-
UNSPSC39121606
-
IDEA Index ID11197139
-
Package DescriptionEACH
-
Standards/ApprovalsCE Certified|CSA C22.2 File No.700489/248.12|UL 248-12 File No.E162363 Guide JDDZ
-
Specification Sheet
-
Owners/User Manual
Recently Viewed
Edison ECNR60 ECNR Current Limiting Time Delay Fuse, 60 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5, Cylindrical Body
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
Edison ECSR10 ECSR Current Limiting Time Delay Fuse, 10 A, 600 V, 200 kAIC Interrupt, Class: RK5, Cartridge Body
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
Leviton® 1451-2 Grounding AC Quiet Toggle Switch, 120 V AC, 15 A, 1/2, 2 hp Power Rating
Tried-and-true toggle designs, Leviton® residential grade AC quiet switches cover all the bases, they install easily and are available in standard and illuminated versions. Their toggles and frames are constructed of impact resistant thermoplastic and they feature large head, hardened triple drive screws for easy installation. Leviton® traditional switches are compatible with a wide range of Leviton® plastic and metal wallplates.
Stanley® STMT74866 Combination Wrench Set, 10 Pieces, 7 to 17 mm, Polished Chrome
Proto® J3300A Angled Head Short Standard Length Open End Wrench Set, Imperial, 9 Pieces, 7/32 to 1/2 in, Satin
SINGLE GROOVE A OR B-BELT SHEAVE9.35X7-1/2-BRW1TB90 >