Littelfuse® POWR-GARD® JTD300 Current Limiting Time Delay Fuse, 300 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
-
BrandLittelfuse®
-
UPC079458202328
-
Manufacturer Part NumberJTD300
-
CountryUSA|Canada
-
Terminal TypeKnife Blade
-
MaterialMelamine
-
ClassJ
-
TypeCurrent Limiting
-
Mounting TypeHolder
-
Voltage Rating600 V AC/500 V DC
-
Amperage Rating300 A
-
SeriesJTD
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating200/20 kA
-
Body Size2 in Dia x 7-1/8 in L
-
Body TypeCartridge
-
ElementDual
- Reduced down time - A glance at the indicating window of a JTD_ID indicator fuse pinpoints open fuses immediately
- Machine operators can immediately determine that there is an open fuse and request maintenance personnel to bring the proper replacement
- Reduce nuisance opening - indicator fuses have superior time-delay and cycling characteristics they can be used on a variety of applications, thus decreasing fuse inventory
- Reduce fuse inventory - Because JTD_ID indicator fuses have superior performance characteristics they can be used on a variety of applications, thus decreasing fuse inventory
- Reduce equipment damage - indicator fuses provide superior overload and short circuit protection that can reduce equipment damage
- Indicator fuses also provide IEC type II "No Damage" protection to IEC and NEMA type motor starters
- Reduce accidents the JTD_ID indicator fuse improves safety by minimizing exposure to live circuits
- IEC type 2 protection
- 200 kA rms symmetrical at 600 VAC/20 kA at 500 VDC
| Competitor Name | Cross-Reference Number |
|---|---|
| Grainger | 486J96 |
-
Alternative Part Number0JTD300.X|8580887
-
UNSPSC39121609
-
IDEA Index ID8580887
-
Package DescriptionEACH
-
Standards/ApprovalsUL 248-8 File No.E81895|CSA File No.LR29862|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® JTD300 Current Limiting Time Delay Fuse, 300 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
Edison ECNR75 ECNR Current Limiting Time Delay Fuse, 75 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
Littelfuse® POWR-GARD® JTD600 Current Limiting Time Delay Fuse, 600 A, 600 V AC/500 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
Edison ECNR3.2 ECNR Current Limiting Time Delay Fuse, 3.2 A, 250 V AC/125 V DC, 200 kAIC Interrupt, Class: RK5
Edison's UL Class RK5 dual-element, time-delay fuses provide economical solutions to overcurrent protectioni. Available in both 250Vac and 600Vac, with 200kA RMS Sym interrupting ratings and sizes ranging from 0 to 600 amp.
EATON BR115 Type BR Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Trip
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
Connecticut Electric View-Pak™ VPKUBIF030N UBIF Type NC Thin Replacement Circuit Breaker, 120 V AC, 30 A, 10 kA Interrupt, 1 Poles
Connecticut Electric View-Pak™ VPKUBIF030N UBIF Type NC Thin Replacement Circuit Breaker, 120 VAC, 30 A, 10 kA Interrupt, 1 Poles, Thermal/Magnetic Trip