Littelfuse® POWR-GARD® JLS125 High Speed Fast Acting Fuse, 125 A, 600 V AC, 200 kA Interrupt, J Class, Cartridge Body
JLS series fuses provide space-saving, fast acting overload and short circuit protection for non-inductive loads. When used for motors or other inductive loads, the ampere rating of JLS series fuses must be increased to prevent nuisance opening on inrush currents. In such applications, JLS fuses may provide only short circuit protection.
-
BrandLittelfuse®
-
UPC079458200843
-
Manufacturer Part NumberJLS125
-
CountryUSA|Canada
-
Terminal TypeKnife Blade
-
MaterialMelamine
-
ClassJ
-
Frequency Rating50/60 Hz
-
TypeHigh Speed
-
Mounting TypeBolt
-
Voltage Rating600 V AC
-
Amperage Rating125 A
-
SeriesJLS
-
Indicating/Non-IndicatingNon-Indicating
-
Interrupt Rating200 kA
-
Body Size1-1/2 in Dia x 5-3/4 in L
-
Body TypeCartridge
-
ElementSingle
- Space saving - JLS fuse characteristics are similar to KLNR/KLSR fast acting class RK1, but they are much smaller
- Extremely current limiting - stops damaging short circuit current faster than any mechanical protective device
- Fast acting - provides fast acting protection to equipment such as variable speed drives, rectifiers and other equipment containing surge-sensitive components
- Longer equipment life - current-limiting design reduces damage to equipment caused by heating and magnetic effects of short circuit currents
- Economical - extremely current-limiting design often permits use of readily available, less costly equipment
- Easy to use
- North American style
- 200 kA at 600 VAC rms symmetrical
| Competitor Name | Cross-Reference Number |
|---|---|
| Grainger | 486J53 |
-
Alternative Part Number0JLS125.X|8580552
-
UNSPSC39121627
-
IDEA Index ID8580552
-
Package DescriptionEACH
-
Standards/ApprovalsUL 248-8|E81895|CSA LR29862|Federal Specification WF-1814 (QPL-W-F-1814)|PROP65: This product can expose you to chemicals including nickel, which is known to the State of California to cause cancer
-
Specification Sheet
-
Owners/User Manual
-
Full Engineering Drawing
-
Technical Bulletin
Recently Viewed
Littelfuse® POWR-GARD® JLS125 High Speed Fast Acting Fuse, 125 A, 600 V AC, 200 kA Interrupt, J Class, Cartridge Body
JLS series fuses provide space-saving, fast acting overload and short circuit protection for non-inductive loads. When used for motors or other inductive loads, the ampere rating of JLS series fuses must be increased to prevent nuisance opening on inrush currents. In such applications, JLS fuses may provide only short circuit protection.
Littelfuse® POWR-GARD® JTD008ID Current Limiting Time Delay Fuse, 8 A, 600 V AC/300 V DC, 200/20 kA Interrupt, J Class, Cartridge Body
The Littelfuse® POWR-PRO® JTD_ID Indicator Class J fuse provides visual blown fuse indication and maximum protection in a compact package. The compact Class J package was designed specifically for circuits where space is at a premium. The current limiting time delay JTD_ID offers a patented true dual-element design that is ideal for use in circuits with high inrush currents. Superior performance characteristics of JTD_ID Indicator fuses reduce nuisance fuse opening and the blown fuse indication reduces downtime and increases safety.
Littelfuse® POWR-GARD® JLS300 High Speed Fast Acting Fuse, 300 A, 600 V AC, 200 kA Interrupt, J Class, Cartridge Body
JLS series fuses provide space-saving, fast acting overload and short circuit protection for non-inductive loads. When used for motors or other inductive loads, the ampere rating of JLS series fuses must be increased to prevent nuisance opening on inrush currents. In such applications, JLS fuses may provide only short circuit protection.
3/4" PLASTIC INSERT TEES-JWH424767 >
BLACK DOOR CLOSER-NTL184788 >
To improve the field of view for deep body fixtures, a separate offset adapter accessory (OSFOA-00W) can be used to position the sensor below the fixture body. The adapter simply snaps into a 1/2 in knockout ON the end of the industrial fixture to attach the sensor.