Steel City® AB-884RBGK001 Raintight Enclosure With Screw Cover, 8 in W x 4 in D x 8 in H, NEMA 3R, 16 ga Steel
-
BrandSteel City®
-
UPC785991041644
-
Manufacturer Part NumberAB-884RBGK001
-
CountryUSA
-
FinishGalvanized
-
Material16 ga Steel
-
ColorGray
-
Mounting TypeSurface
-
NEMA RatingNEMA 3R
-
Height8 in
-
Width8 in
-
Depth4 in
| Cross-Reference Number |
|---|
| 538485 |
-
Alternative Part Number7TAA001640R0008|10720027
-
UNSPSC39121324
-
IDEA Index ID10720027
-
Package DescriptionEACH
-
Standards/ApprovalsUL Listed
-
Warranty2 years Limited
Recently Viewed
Carlon® E998G Non-Metallic Service Entrance Cap, 1-1/4 in, 0.71 in Hole, For Use With SCH 40 and SCH 80 Rigid Non-Metallic Conduit, PVC
Carlon® E998G Non-Metallic Service Entrance Cap, 1-1/4 in, 0.71 in Hole, For Use With SCH 40 and SCH 80 Rigid Non-Metallic Conduit, PVC
Carlon® E998E Service Entrance Cap, 3/4 in, 0.45 in Hole, For Use With SCH 40 and SCH 80 Rigid Non-Metallic Conduit, PVC
Carlon® E998E Service Entrance Cap, 3/4 in, 0.45 in Hole, For Use With SCH 40 and SCH 80 Rigid Non-Metallic Conduit, PVC
Browning® 1022193 MVP® Type 15 Web Companion Sheave, 1-3/8 to 3-5/8 in Bushed Bore, 10.4 in OD, 5 Grooves, 10.4 in Dia Pitch, 7-7/8 in W Face
MVP® sheaves are a series of angular faced center flanges which are bolted to the fixed flange mounted on the barrel. They also contain another series of angular faced flanges which are bolted to the end flange and threaded locking collar. When the threaded locking collar is turned clockwise, it moves the angular flanges closer together increasing the pitch diameter. When the collar is moved counterclockwise, the flanges are moved apart, decreasing the pitch diameter. The pitch diameter is infinite. This means the collar adjustment can be turned and stopped at any time regardless of location between the minimum and the maximum setting. When the desired diameter is obtained, the locking collar is locked by tightening screws. In contrast VL, VP, and VM sheaves are limited by half- turn or 180 deg adjustment points.
Appleton® NEER™ AC95 Non-Insulated Conduit Connector With Locknut, 1/2 in Trade, For Use With Armored/FMC/Metal Clad Cable, Die Cast Zinc, Natural/Zinc Plated
Appleton® offer NEER™ zinc cable and conduit connectors for terminating flexible metal conduit in a dry location box or enclosure, or joining lengths of flexible metal conduit. Type SC straight squeeze connectors, Type AC 90 deg two screw clamp connectors and Type DC-5500 duplex, single screw, clamp connectors are used to make a termination of flexible metal conduit. Type FC set screw connectors are used to terminate 1/2 in regular wall steel or aluminum flexible conduit. Type GC screw-in connectors are for use with flexible metal conduit. Type GX screw-in connectors are used to join lengths of flexible metal conduit.

