Cutler-Hammer CH270 Type CH Standard Molded Case Circuit Breaker, 120/240 V AC, 70 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. These features further establish the CH series of products as Best in Class. Eaton offers CH 3/4 in circuit breakers with a thermal-magnetic trip curve that avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions.
-
BrandCutler-Hammer
-
UPC782113101897
-
Manufacturer Part NumberCH270
-
CountryUSA
-
Temperature Rating40 deg C
-
MaterialBakelite
-
Trip TypeThermal Magnetic
-
ColorBlack
-
TypeType CH Standard
-
Mounting TypePlug-On
-
Actuator Type2-Position Handle
-
Voltage Rating120/240 V AC
-
Amperage Rating70 A
-
Wire Size14 to 2 AWG
-
Number of Poles2
-
Dimensions3 in H x 3/4 in W x 3-1/2 in D
-
Interrupt Rating10 kA
-
Enclosure TypeNEMA 1/3R
-
Phase1
- Space-saving 3/4 in design accommodates more breakers per panel
- Tri-Drive screw accepts flat, Robertson or Phillips drivers, making it easier for electricians to install
- Units feature a quick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip-free handle design
- Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks
- CH interiors feature 100% copper bus
- Cu/Al wire
- Two pole requires two 3/4 in (19.1 mm) space
-
UNSPSC39121616
-
Standards/ApprovalsUL File E8741 Listed|HACR Rating|Federal Specification W-C 375 b/Gen
-
Catalog
Recently Viewed
Cutler-Hammer CH270 Type CH Standard Molded Case Circuit Breaker, 120/240 V AC, 70 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. These features further establish the CH series of products as Best in Class. Eaton offers CH 3/4 in circuit breakers with a thermal-magnetic trip curve that avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions.
OIL FILTER-WIX51748>
1-1/4" -ID JAW COUPLING HALVES-BRWL225X11/4 >
HEAVY DUTY 4-WHEEL DRUM TRUCK - MOD74VR >
Edison offers a complete line of Class CC fuses to meet your circuit and equipment protection needs. These branch circuit rated compact fuses rated 600v, and delivering 200,000a IR Vac Sym provide excellent protection in the smallest package of any UL class of fuses. Choose from our EDCC time-delay fuses for your small horsepower motor circuits, our HCLR fast-acting for your non-inductive lighting and resistance heating loads or our HCTR time-delay fuses for your small control transformer protection.
4-GRV BANDED 5-V X-1600 V-BELT-PIX5VX1600/04 >