EATON CH225 Type CH Standard Molded Case Circuit Breaker, 120/240 VAC, 25 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
EATON has enhanced its premium Type CH residential circuit breakers, making the best even better. These features further establish the CH series of products as Best in Class. EATON offers CH 3/4 in circuit breakers with a thermal-magnetic trip curve that avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions.
-
BrandCutler-Hammer
-
UPC782113121451
-
Manufacturer Part NumberCH225
-
CountryUSA
-
Temperature Rating40 deg C
-
MaterialBakelite
-
Trip TypeThermal Magnetic
-
ColorBlack
-
TypeType CH Standard
-
Mounting TypePlug-On
-
Actuator Type2-Position Handle
-
Voltage Rating120/240 V AC
-
Amperage Rating25 A
-
Wire Size(1) 14 to 8 AWG, (2) 14 to 10 AWG
-
Number of Poles2
-
Dimensions3-1/2 in L x 1-1/2 in W x 3-1/2 in H
-
Interrupt Rating10 kA
-
Enclosure TypeNEMA 1/3R
-
Phase1
- Space-saving 3/4 in design accommodates more breakers per panel
- Tri-drive screw accepts flat, Robertson or Phillips drivers, making it easier for electricians to install
- Single and 2-pole breakers up to 50 A
- Units feature a quick-make, Quick-break switch mechanism combined with inverse time element tripping operation and trip-free handle design
- Type CH circuit breakers trip to the Off position, eliminating nuisance call backs
- Type CH interiors feature 100% copper bus
- Copper/aluminum wire
- 2-pole requires two 3/4 in space
-
Alternative Part Number7337153
-
UNSPSC39121601
-
IDEA Index ID7337153
-
Package DescriptionEACH
-
Standards/ApprovalsCCC Certified|CE Certified|CSA Certified|Lloyd's Register Certified|Bureau Veritas Certified|GOST-R Certified|UL 489
-
WarrantyLimited Lifetime
-
Catalog
Recently Viewed
EATON CH225 Type CH Standard Molded Case Circuit Breaker, 120/240 VAC, 25 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
EATON has enhanced its premium Type CH residential circuit breakers, making the best even better. These features further establish the CH series of products as Best in Class. EATON offers CH 3/4 in circuit breakers with a thermal-magnetic trip curve that avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions.
DRILLCO 440N514 Type B Heavy Duty Jobber Length Drill Bit, N Drill - Letter, 0.302 in Drill - Decimal Inch, 135 deg Point, HSS, Oxide Treated
Nitro® drills (NAS Type B) offer superior performance over standard HSS drills. Heavy-duty design increases tool life and performance. 135° Split Point reduces walking at the point. Ideal for both hand held and CNC Operations. Black & Gold.
DRILLCO 440N525 Type B Heavy Duty Jobber Length Drill Bit, Y Drill - Letter, 0.404 in Drill - Decimal Inch, 135 deg Point, HSS, Oxide Treated
Nitro® drills (NAS Type B) offer superior performance over standard HSS drills. Heavy-duty design increases tool life and performance. 135° Split Point reduces walking at the point. Ideal for both hand held and CNC Operations. Black & Gold.
DRILLCO 440N519 Type B Heavy Duty Jobber Length Drill Bit, S Drill - Letter, 0.348 in Drill - Decimal Inch, 135 deg Point, HSS, Oxide Treated
Nitro® drills (NAS Type B) offer superior performance over standard HSS drills. Heavy-duty design increases tool life and performance. 135° Split Point reduces walking at the point. Ideal for both hand held and CNC Operations. Black & Gold.
DRILLCO 400N29 Heavy Duty Jobber Length Drill Set, 1/16 in Min Drill Bit, 1/2 in Max Drill Bit, 135 deg Drill Point Angle, 29 Pieces, HSS, Oxide Treated
Nitro® drills (NAS Type B) offer superior performance over standard HSS drills. Heavy-duty design increases tool life and performance. 135° Split Point reduces walking at the point. Ideal for both hand held and CNC Operations. Black & Gold.
EATON CHB220 Type CHB Standard Molded Case Circuit Breaker, 120/240 V AC, 20 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.