EATON BR120 Type BR Circuit Breaker, 120/240 V AC, 20 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Trip
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
-
BrandEATON
-
UPC786676362108
-
Manufacturer Part NumberBR120
-
CountryUSA
-
Temperature Rating600 to 750 deg C
-
Trip TypeThermal Magnetic
-
TypeType BR
-
Mounting TypePlug-On
-
Voltage Rating120/240 V AC
-
Amperage Rating20 A
-
Wire Size14 to 4 AWG
-
Number of Poles1
-
Dimensions2-1/2 in L x 1 in W x 3 in H
-
Interrupt Rating10 kA
-
Enclosure TypeNEMA 1/4X/3R
-
Phase1
- Common trip requires one 1 in space
- All BR circuit breakers have rejection tab feature
- Units feature a quick make, quick break switch mechanism combined with inverse time element tripping operation and trip free handle design
- For 1-pole circuit breakers carry listing for HACR application
| Competitor Name | Cross-Reference Number |
|---|---|
| Ferguson | CBR120 |
-
Alternative Part Number7434383
-
UNSPSC39121601
-
IDEA Index ID7434383
-
Package DescriptionEACH
-
Standards/ApprovalsUL 489,Federal Specifications Classification W-C375
-
Warranty10 years
-
Specification Sheet
-
Line Drawing
-
Catalog
Recently Viewed
EATON BR120 Type BR Circuit Breaker, 120/240 V AC, 20 A, 10 kA Interrupt, 1 Poles, Thermal Magnetic Trip
Eaton’s BR circuit breakers are used in indoor and outdoor BR loadcenters, spa panels, meter breakers and sub panels. They are designed for a wide range of applications such as high short-circuit interrupt, series rating combinations with upstream main breakers, thermal magnetic, AFCI, GFCI, equipment protection and dual function AF/GF.
Bussmann LKS-100 Non-Current Limiting Renewable Class H Fuse Link, 600 V, 100 A, For Use With RES-100 Class H 7.88 in L Fuse
Bussmann LKS-100 Non-Current Limiting Renewable Class H Fuse Link, 600 V, 100 A, For Use With RES-100 Class H 7.88 in L Fuse
Littelfuse® POWR-GARD® FLSR.800ID Current Limiting Time Delay Fuse, 0.8 A, 600 V AC/300 V DC, 200/20 kA Interrupt, RK5 Class, Cylindrical Body
Littelfuse® FLSR series fuses have been the superior UL Class RK5 dual element time delay fuses and are the most widely used Class of fuses. FLSR series fuses provide excellent protection for all types of circuits especially those containing motors. However, users and specifiers should consider the significant benefits offered by indicator fuses.
MORSE® 18003 8000 3-in-1 Combination General Purpose Jobber Length Drill Set, 118 deg Drill Point Angle, 115 Pieces, HSS, Black Oxide
United Abrasives-SAIT 27035 Mounted Point, A5, 3/4 in Dia x 1-1/8 in L Head, 1/4 in Dia Shank