DRILLCO 7A124ADC 7000A Wheel Brush, No End Cut End, Cylindrical Head, 3/8 in Dia Head, 3/4 in L of Cut, Double Cut
Drillco solid carbide burrs are extremely versatile. Manufactured from premium grade tungsten carbide. Burrs are available in standard lengths (single and double cut), 6" long series, and in miniature sizes (for use in pencil grinders).
-
BrandDrillco
-
UPC045997294131
-
Manufacturer Part Number7A124ADC
-
CountryUSA|Canada
-
Maximum Speed40000 rpm
-
Head Diameter3/8 in
-
Head MaterialSolid Carbide
-
Head ShapeCylindrical
-
Applicable MaterialsAluminum, Brass, Cast Iron, Copper, Magnesium Plastics, Steel and Stainless Steel
-
Series7000A
-
Cut TypeDouble
-
Shank Diameter1/4 in
-
Industry SpecificationSA-3
-
End TypePlain
-
Length of Cut3/4 in
- Double cut tooth design for aggressive material removal
- Optimal flute geometry for fast removal and fine finish
- Brazed shank for perfect concentricity and reduced vibrations
- The double cut design also produces an easy to handle granular type chip, in most metals, as opposed to the conventional sliver type chips
- Throughout it's life, the double cut gives faster stock removal, less operator fatigue, and maintains a good finish on the widest possible variety of materials
- Double cut tooth design for aggressive material removal
- Optimal flute geometry for fast removal and fine finish
- Brazed shank for perfect concentricity and reduced vibrations
-
UNSPSC23251706
-
Package Description1/PK
-
Standards/ApprovalsPROP65: This product can expose you to chemicals including Cobalt, which is [are] known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov
-
SDS
-
Catalog
Recently Viewed
DRILLCO 7A124ADC 7000A Wheel Brush, No End Cut End, Cylindrical Head, 3/8 in Dia Head, 3/4 in L of Cut, Double Cut
Drillco solid carbide burrs are extremely versatile. Manufactured from premium grade tungsten carbide. Burrs are available in standard lengths (single and double cut), 6" long series, and in miniature sizes (for use in pencil grinders).
Drillco 76A132C 7600 Center Cutting Imperial Regular Length Single End Ball Nose End Mill, 1/2 in Dia Cutter, 1 in Length of Cut, 2 Flutes, 1/2 in Dia Shank, 3 in OAL, Uncoated
Solid carbide end mills run at extremely impressive feed and speed rates. In some cases, they can be run at 3x the rates of HSS end mills. Using solid carbide end mills results in better surface finish on the workpiece and extended tool life. Ball nose.
Drillco 77A116C 7700 Center Cutting Imperial Regular Length Single End Ball Nose End Mill, 1/4 in Dia Cutter, 3/4 in Length of Cut, 4 Flutes, 1/4 in Dia Shank, 2-1/2 in OAL, Uncoated
Solid carbide end mills run at extremely impressive feed and speed rates. In some cases, they can be run at 3x the rates of HSS end mills. Using solid carbide end mills results in better surface finish on the workpiece and extended tool life. Ball nose.
EATON CH215GFT Type CH Self-Test Ground Fault Circuit Breaker, 120/240 V AC, 15 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON CH250GF Type CH Ground Fault Circuit Breaker, 120/240 V AC, 50 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip
Quick-make, quick-break switch mechanism combined with inverse time element tripping operation and trip-free handle design. Type CH circuit breakers trip to the off position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off the thermal magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short circuit conditions. Multi-pole breakers have internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.