Load Center Neutral & Ground Bars
EATON GBK10P Ground Bar Kit, 3/4 in L, Aluminum/Copper Conductor, 10 Terminals, For Use With Type CH/BR Loadcenter and Circuit Breaker
Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
EATON GBK14P Ground Bar Kit, 5-3/4 in L, Aluminum/Copper Conductor, 14 Terminals, For Use With Type CH/BR Loadcenter and Circuit Breaker
Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
Square Dâ„¢ QOâ„¢ PK4GTA Equipment Ground Bar Assembly, 1.63 in L, 14 to 4 AWG, 4 Terminals, For Use With QOâ„¢ Load Center and Type PK Circuit Breaker
By grounding the system, it helps prevent electrical shock hazards and ensures that stray electrical currents are safely directed to the earth. It acts as a centralized location where all ground wires from branch circuits are securely connected. It provides a neat and organized way to terminate multiple ground conductors, making the panel easier to inspect and maintain. This is a Ground Lug kit compatible for both QO and Homeline Load Center. It has 4 number of circuits which accepts (1) 14 4 or (2) 14 or 12AWG copper or (1) 12 4 or (2) 12 or 10AWG aluminum.
Square Dâ„¢ QOâ„¢ PK7GTA Equipment Ground Bar Assembly, 2.88 in L, 14 to 4 AWG, 7 Terminals, For Use With QOâ„¢ Load Center and Type PK Circuit Breaker
By grounding the system, it helps prevent electrical shock hazards and ensures that stray electrical currents are safely directed to the earth. It acts as a centralized location where all ground wires from branch circuits are securely connected. It provides a neat and organized way to terminate multiple ground conductors, making the panel easier to inspect and maintain. This is a Ground Lug kit compatible for both QO and Homeline Load Center. It has 7 number of circuits which accepts (1) 14 4 or (2) 14 or 12AWG copper or (1) 12 4 or (2) 12 or 10AWG aluminum.